User's Manual
Digital Monitoring Products
CellComSL
Series Communicator Install/Programming Guide
28
APPENDIX
18.8 Zone Type Defaults
The communicator contains nine default zone types that provide the most commonly selected functions for their
applications.Allzonetypescanbecustomizedbychangingthevariableoptionslistedbelow.
Type -Thesearetheabbreviationsdisplayedonthekeypadforthezonetypes.
Area -UseArea1.
Message -A=alarmreport,T=troublereport,
L=localwithnoreport,—(dash)=noreport.
Output -The1to2switchedground(opencollector)outputs.
Action - This selects the type of relay output:
S=steady,P=pulse,M=momentary,andF=follow
Swinger Bypass - The zone can be automatically bypassed after a programmed number of trips.
Cross Zone - Provides cross zoning for this zone.
Receiver Routing -ThisselectstheroutingoptionforAuxiliary1orAuxiliary2zonetypes.
Style-Theabbreviationsthatdisplayonthekeypadforarmingzonestyle.
TGL=Toggle,
ARM=Armonly,DIS=Disarmonly,
STEP=Wirelessarming,MNT=Maintain
18.10Z-WaveCerticationInformation
The
CellComSL
CZisasecurityenabledZ-Waveproductandisdesignedtobeusedasaprimarycontroller.
TheXFERfeatureallowsanexisting3rdpartynetworktobetransferredintothe
CellComSL
CZ.
The
CellComSL
CZcansupportZ-Waveproductsfromdifferentvendorsandproductcategories.Itisrecommended
to use devices listed on the buy.dmp.com site for best performance.
Z-Waveterminology:
• InclusionistheprocessofaddingadevicetotheZ-Wavenetwork.Thenewdeviceis‘included’intothe
Z-Wavenetwork.
• ExclusionistheprocessofremovingadevicefromtheZ-Wavenetwork.Thenewdeviceis‘excluded’
fromtheZ-Wavenetwork.
• Replicationistheprocessofcopyingnetworkinformationtoanotherdevice(typicallyaZ-Wavecontroller)
intheZ-Wavenetwork.
18.11 Backlit Logo
ThebacklitlogoindicatesthePowerandArmedstatusofthecommunicator.Dependingontheoperation,the
LEDdisplaysinRedorGreenaslistedinthetable.TheLEDindicatesthestatusofthesystembatteryand
primary power.
Color and Activity Operation
GreenSteady CommunicatorDisarmed,PrimaryPowerOK,BatteryOK
GreenBlinking CommunicatorDisarmed,PrimaryPowerOK,BatteryFault
NoLight CommunicatorDisarmed,PrimaryPowerFault,BatteryOK
RedSteady CommunicatorArmed,PrimaryPowerOK,BatteryOK
Red/GreenAlternate CommunicatorArmed,PrimaryPowerOK,BatteryFault
RedBlinking CommunicatorArmed,PrimaryPowerFault,BatteryOK