applIcatIons
Applications
TheCellComSLSeriesCommunicatorcanbeusedinavarietyofapplications:
3.1 CID
Dialer Connection
Directlyconnectthetelcophoneline(tipandring)fromthecontrolpaneltotheCellComSLtocaptureContact
IDmessagesthatarebasedontheSIAcommunicationstandardDC-05-1999.09-DCS. These messages are
thenformattedintoaSerial3messageandsenttoaDMPModelSCS-1RorSCS-VRReceiver.Note:CIDDialer
ConnectioncannotbeusedwhenusingZone4BellConnection.
3.2 Zones 1 - 4 Input Connection
ConnecteachburglarycontrolpanelrelayoutputtoaCellComSLSeriesCommunicatorzone.Forprogramming
purposes,thezonenumbersare1-4.(SeeFigure10forwiringdetails).Anexampleofhowyoumightusethis
application:Youcanuseanormallyclosedoutputontheburglarycontrolpaneltoindicateaburglaryalarm.The
CellComSLzoneshouldbeprogrammedwithazonenameandzonetypeofBurg.Whentheoutputonthecontrol
panelturnsonandtripstheCellComSLzone,amessagewillbesenttoanSCS-1RorSCS-VRreceiveratCentral
Station.Youcouldusethezonenameprogrammingtodescribewhichcontrolpanelzoneindicatedaburglary.
Note:Zone4canonlybeusedasastandardinputzonewhennotprogrammedaszonetypeAuxiliary2(A2).See
Zone4BellConnection.
Figure 9: CellComSL Series Wiring Diagram for Tip and Ring Connection
Use 18-22 AWG for
Power Supply connection
Z3 +
Z4 +
Z4 -
GND
12 VDC Aux. Output
+
-
Ground
Control Panel
The panel or separate power
supply must be 12 Volt Regulated
and Power Limited.
Z1 +
Z2 +
RESET
S1
LOAD
S2
BAT
PROG
S
N
+12 G Z1 Z2 Z4-Z4+GZ3 RTO2O1
RB
Normally Open
Common
Normally Closed
Normally Open
Common
Normally Closed
Normally Open
Common
Normally Closed
Normally Open
Common
Normally Closed
J8
J26
J9
S1
S2
S3
1k ohm
1k ohm
1k ohm
1k ohm
MODEL
CellComSLC
Figure 10: CellComSL Series Wiring Diagram for Zones 1 - 4
Use 18-22 AWG for
Power Supply connection
CONTROL PANEL TIP
CONTROL PANEL RING
12 VDC Aux. Output +
-
Ground
Control Panel
The panel or separate power
supply must be 12 Volt Regulated
and Power Limited.
Telephone
Jack
Connector
BELL -
BELL +
RESET
S1
LOAD
S2
BAT
PROG
S
N
+12 G Z1 Z2 Z4-Z4+GZ3 RTO2O1
RB
J8
J26
J9
S1
S2
S3
MODEL
CellComSLC