User's Manual

CellComSL
Series Universal Communicator Installation and Programming Guide Digital Monitoring Products
7
remote armIng/dIsarmIng
Remote Arming/Disarming
4.1 DMP Virtual Keypad App / Virtual Keypad Browser
UsingaSmartphonewiththeDMPVirtualKeypadApporusingacomputerwiththeVirtualKeypadBrowser
(www.myvirtualkeypad.com),youcanconnecttotheCellComSLSeriesCommunicatortoarmAreas,turnOutputs
onandoff,andadd,editorremoveUsers.WhenusingtheCellComSLCZ,youcancontrolZ-Wavedevices,
Favorites and Rooms.
Figure 12: Virtual Keypad Application can be used to access the CellComSL Series Communicator.
AburglarycontrolpanelzonemaybeprogrammedasanarmingzoneandconnectedtoaCellComSLoutput
(O1orO2)(SeeFigure13).ProgramtheoutputnumberinArmedOutputorRemoteArmingOutputinOutput
OptionsoftheCellComSL(SeeArmedOutputorRemoteArmingOutput).TheCellComSLCommunicatoroutput
connectionscanbeusedwithanyoftheapplicationslistedinApplicationsSection.
Use 18-22 AWG for
Power Supply connection
O1
O2
12 Vdc Aux. Output
+
-
Control Panel
BAT
MODEL CellComSL
PROG
+12 G Z1 Z2 Z4-Z4+GZ3 RTO2O1
RB
GND
Zone 1
Zone 2
Control Panel EOL resistor
Figure 13: Burglary control panel zones connected to the CellComSL Series outputs to
arm and disarm the burglary control panel.