16
system optIons
11.5 Power Fail Delay
Thisoptiontracksthedurationofaprimarypowerfailure.Thedelaytimecanbefrom1
to9hours.Whenthepowerisoffforthelengthoftheprogrammeddelaytime,apower
failure report is sent to the receiver. For example, if the power failure delay is set for
twohours,thenthepowerfailurereportwillbesentbetween2-3hours.Enteringa0
(zero) sends the power failure report within 15 seconds.
11.6 Swinger Bypass Trips
Enterthenumberoftimes(1-6)azonecangointoanalarmortroubleconditionwithin
one hour be fore being auto matically bypassed. Bypassed zones are auto matically reset
whentheareatheyareassignedtoisdisarmed.All24-hourzonesareresetwhenany
areaofthesystemisdisarmed.AprogrammingStopoperationrestoresabypassedzone.
Entering0(zero)disablesthisfunction.Defaultis2.
How it works
The communicatorhourtimerstartsat59minutespastthehour.Ifthehourtimer
expiresbeforethetripcounterisexceeded,thetripcounterreturnsto0(zero).Ifthe
trip counter is exceeded before the hour expires, the zone is auto matically bypassed by
the communicator.ABypassReportissenttothereceiverifBypassReportsisYES.
11.7 Reset Swinger Bypass
WhenYESisselected,anautomaticallybypassedzoneisresetifitremainsinanormal
conditionforonecompletehourafterbeingbypassed.Areportoftheautomaticresetis
senttothereceiverifBypassReportshasbeenselectedasYES.DefaultisNO.
11.8 Time Changes
This option allows the communicatortorequestautomatictimechangesfromtheDMP
SCS-1RorSCS-VR Receiver. For the receiver to send time changes, it must be
programmed to send time changes and must be receiving time change updates from the
hostautomationcomputeratleastevery24hours.DefaultisYES.
WhentimezoneisprogrammedYES,enterthenumber(0-23)thatindicatesthe
GreenwichMeanTimezone(GMT)wherethecommunicator is located. The default is 6.
SeetablebelowforGMTvalues.
GMT City/Time Zone GMT City/Time Zone
0 London, Monrovia, Lisbon 12 Fiji, Marshall Island, Wellington
1 Cape Verde Island, Azores 13 New Cadelonia
2 Mid-Atlantic 14 Guam, Sydney
3 Buenos Aires, Georgetown 15 Tokyo, Seoul
4 Atlantic Time (Canada), Caracas 16 Hong Kong, Singapore
5 Eastern Time (US, Canada) Bogota 17 Bangkok, Hanoi
6 Central Time (US, Canada) Saskatchewan 18 Dhaka, Almaty
7 Mountain Time (US, Canada), Edmonton 19 Islamabad, Karachi
8 Pacic Time (US, Canada), Tijuana 20 Abu Dhabi, Kazan
9 Alaska 21 Moscow, Bagdad
10 Hawaii 22 Eastern Europe
11 Midway Island, Samoa 23 Rome, Paris, Berlin
11.9 Keypad Input
ThisoptionallowstheCellComSLtocommunicatewithAdemco/Honeywellpanelsover
theAdemco/HoneywellECPBususingthezone4+andzone4-terminals.
ThisallowsthecommunicatortoaddanddeleteUserCodesaswellasArmandDisarm
theAdemco/Honeywellpanel.
ExistingusercodesintheAdemco/Honeywellpanel,includingMaster,mustbeadded
totheCellComSL.AnynewusercodesaddedtotheCellComSLfromtheAppwillbe
automaticallyenteredintheAdemco/Honeywellpanel.
Note:UsercodesfromtheAdemco/HoneywellpanelthataredesignatedasMasteror
PartitionMastershouldbeconguredasMastercodesintheCellComSL.
SelectECPtoenablecommunication.WhenNONEisselected,zone4functionsasaBell
input.DefaultisNONE.
SeeProgrammingforAdemcoVista20PECPtoCellComSLandFigure19forpanelwiring
intheAppendixfornecessaryAdemco/Honeywellpanelprogramming.
PWR FAIL HRS: 1
SWGRBYPS TRIPS: 2
RST SBYP NO YES
TIME CHG NO YES
HRS FROM GMT: 6
KYPD INPUT
NONE ECP