User's Manual

Digital Monitoring Products
CellComSL
Series Universal Communicator Installation and Programming Guide
18
area InformatIon
13.4 Automatic Arming
SelectYEStoallowthisareatoarmautomaticallyaccordingtotheopeningandclosing
schedule.
Atarming,faultedzonesarehandledaccordingtotheoptionselectedinBadZones.If
aClosingreportissent,theusernumberisindicatedasSCHontheSCS-1RorSCS-VR
Receivers.SelectNOtodisableautomaticarmingforthisarea.DefaultisNO.
13.4.1 Bad Zones
Atthetimeofautomaticarming,somezonesintheareamaynotbeinanormal
condition.Thisoptionallowsyoutoprogramthepanel’sresponsetothesebadzones.
ThisoptionisnotdisplayedifAUTOARMisNO.
BYP-Allbadzonesarebypassed.AreportofthebypassissenttothereceiverifBypass
ReportshasbeenselectedasYES.ThereportindicatesSCHastheusernumber.
FORC-Allbadzonesareforcearmed.Zonesforcearmedinabadconditionarecapable
ofrestoringintothesystemandreportingalarmsiftripped.Areportoftheforcearmis
senttothereceiver.ThereportindicatestheusernumberasSCH.
REF-Theautomaticarmingisrefusedandnoarmingtakesplace.Closingreportissent
to the receiver.
13.5 Automatic Disarming
NOdisablesautomaticdisarmingbyscheduleforthisarea.SelectYEStoallowthisarea
toautomaticallydisarmaccordingtoaschedule.IfanOpeningreportissenttothe
receiver,theusernumberisindicatedasSCH.
Zone Information
14.1 Zone Information
Thisallowsyoutodenetheoperationofeachprotectionzoneusedinthesystem.
14.2 Zone Number
The
c
ommunicatorhasfourzonestoprogram.Enterthenumberofthezoneyouintend
toprogram.ToprogramZone4,seeZone4informationonpage2fordetails.Press
COMMANDtoenterazonename.RefertotheEnterAlphaCharacterssection.
14.3 Zone Name
PressanySelectkeyandenterupto16charactersforthezonename.Anamemustbe
given to each zone in the system. The zone name is sent to the receiver as part of a
zone event report.
Azonethatisnotpartofthesystemmustbemarked*UNUSED*.Tomarkazoneunused,
deletetheoldnamebypressinganySelectkey,thenpresstheCOMMANDkey.Thepro-
grammerautomaticallyprogramsthenameas*UNUSED*.IfyouselectedZONES?NO
YEStoclearthecommunicatorsmemoryduringInitialization,thezoneswillalreadybe
marked*UNUSED*.SeeSection6-Initialization.
14.4 Zone Type
TheZoneTypedenestheresponseofthecommunicator to the zone being open or
short.
WhenyouassignaZoneTypetoazone,responsesaremadeautomaticallyforthezone.
Thereare12ZoneTypestochoosefromincludingBlank.
ToselectanewZoneType,pressanySelectkey.ThedisplayliststhefourZoneTypes
shownbelow.WhentheZoneTypeyouwanttoselectdisplays,presstheSelectkey
below the name.
Blank,Night,Day,orExit.PressCOMMANDtodisplayadditionalzonetypes.
Fire,Panic,Emergency,orSupervisory.PressCOMMANDtodisplayadditionalzonetypes.
Auxiliary1,Auxiliary2,FireVerify,orArming.PresstheBackArrowkeytodisplaythe
previous zone types.
IfyouselectBlank,Night,Day,Exit,Auxiliary1,orAuxiliary2(SeeZone4Programming
onPage2)astheZoneType,thezonemustbeassignedtoanarea.IfyouselectFire,
Panic,Emergency,orSupervisoryastheZoneType,theseare24-hourzonesthatare
alwaysarmedandnoareaassignmentisneeded.PressCOMMANDtocontinue.
14.5 Area Assignment
Allnon-24-hourzonesareautomaticallyassignedtoArea1.Entertheareanumberfrom
1 to 6 where this zone is being assigned.
AUTO ARM NO YES
BAD ZONES: BYP
BYP FORC REF
AUTO DIS NO YES
ZONE INFORMATION
ZONE NO: -
* UNUSED *
ZONE TYPE: BLANK
AREA NO: 1
zone InformatIon
A1 A2 AR FV
FI PN EM SV