User's Manual
CellComSL
Series Universal Communicator Installation and Programming Guide Digital Monitoring Products
19
zone InformatIon
14.6 Arming Zone Assignment
ThisoptionspeciestheareastobearmedbytheArmingTypezone.Pressthe
appropriatenumberkeysonthekeypadtoassignareas1to6.Whendisarmed,allareas
are disarmed.
14.7 Style
Thisoptionspeciesthestyleforthearming/disarmingoperation.Thedefaultfor
STYLE:isTGL(Toggle).PressinganySelectkeydisplaystheSTYLEoptions.Toviewmore
styleoptionspressthecommandkey.Thefollowingisadescriptionoftheactionfor
each option condition.
TGL(Toggle)-Whenthezonechangesfromnormaltoshorted,theprogrammedareas
togglebetweenthearmedordisarmedcondition.Whenrestoredtonormal,noaction
occurs.Whenthezoneisopenedfromanormal(disarmed)state,atroubleisreported.
Whenopenedfromashorted(armed)state,analarmisreportedandthezoneis
disableduntilyoudisarmthearea(s)fromeithertheVirtualKeypadApp,MyAccess,
VirtualKeypadBrowseroraRemoteLink™computer.
ARM-Whenthezoneisshorted,theprogrammedareaisarmed.Whenrestoredto
normal,noactionoccurs.Whenthezoneisopenedfromanormal(disarmed)state,a
troubleisreported.Whenopenedfromashorted(armed)state,analarmisreported.
DIS(Disarm)-Ashortwilldisarmthearea.Whenrestoredtonormal,noactionoccurs.
Whenthezoneisopenedfromanormal(disarmed)state,atroubleisreported.
STEP-Ashortwillarmtheareas.Anormalconditionwillcausenoaction.Anopen
condition will disarm the areas.
Note:Whenusinganarming/disarmingkeyswitch,locatethekeyswitchwithinthe
protected area.
MNT(Maintain)-Whenthezoneisshorted,theprogrammedareaisarmed.When
restored to normal, the programmed area is disarmed and any alarm bells are silenced.
Whenthezoneisopenedfromanormal(disarmed)state,atroubleisreported.If
opened from a shorted (armed) state, an alarm is reported and the zone is disabled
untilyoudisarmtheareafromeithertheVirtualKeypadApp,MyAccess,VirtualKeypad
BrowseroraRemoteLink™computer.
14.8 Next Zone
WhenYESisselected,theprogrammingforthezoneterminatesandthedisplayreturns
toZONENO:-allowingyoutoenteranewzonenumber.SelectNOtomakechangesto
theAlarmActionforazone.
14.9 Alarm Action
TheAlarmActionsectionallowsyoutochangeorconrmthedefaultalarm
characteristics of a zone type.
Ifyouselectedthenon-24-hourzonetypeBlank,Night,Day,Exit,Auxiliary1,or
Auxiliary2,theAlarmActionprogramingbeginswithDisarmedOpen.
Ifyouselectedthe24-hourzonetypePanic,Emergency,orSupervisory,theAlarmAction
programmingbeginswithArmedOpen.
14.10 Disarmed Open
Denestheactiontakenbythecommunicator when the zone is opened while the area is
disarmed.Therearethreeactionstodene:
• MessagetoTransmit
• Output/FavoriteNumber
• OutputAction
YoumustalsomaketheseselectionsfortheDisarmedShort,ArmedOpen,andArmed
Shortzoneconditions.PresstheCOMMANDkeytocontinue.
14.11 Message To Transmit
Youcansendtworeporttypestothereceiver:AlarmandTrouble.Thesearerepresented
bythecharactersAandT.PressanySelectkeytodisplaythezonereportoptions.
ALARM-SelectingAallowsanalarmreporttobesenttothereceiver.Thezonename
appears in the communicator’salarmedzonesstatuslists.
TROUBLE-SelectingTallowsatroublereporttobesenttothereceiverandthezone
name to appear in the communicator’salarmedzonesstatuslists.
LOCAL-WhenyouselectL,analarmreportisNOTsenttothereceiver.Thezonename
appears in the communicator’salarmedzonesstatuslists.
–(dash)-Whenyouselect–,reportsareNOTsenttothereceiver.Thereisnodisplay
in the communicator’salarmedzonesstatuslist.OnlytheprogrammedOutputNumber
activates.
AREA: 1 - - - - -
STYLE: TGL
TGL ARM DIS STEP
MNT
NEXT ZN? NO YES
ALARM ACTION . . .
DISARMED OPEN
MSG: ALARM
A T L -