User's Manual
Digital Monitoring Products
CellComSL
Series Universal Communicator Installation and Programming Guide
20
zone InformatIon
14.12 Output Number
Youcanspecifyanyoftheoutputs/Favoritesonthecommunicator to be activated by
a zone condition. The output/Favorite can be activated regardless of the report to
transmitorwhetherornotthezoneisprogrammedaslocal.Anoutputactivatedbya
non-24-hourarmedzoneisturnedoffwhenthezone’sareaisdisarmedbyauser.To
enteranOutputNumber,pressanySelectkeyfollowedbytheoutputnumber1or2.
PresstheCOMMANDkey.
14.13 Output Action
EnteringanOutputNumberdisplaysthispromptthatallowsyoutoassignanoutput
actiontotheoutput.Adescriptionoftheavailableoutputactionsisgivenbelow:
STEADY-Theoutputisturnedonandremainsonuntiltheareaisdisarmed,anoutput
cutofftimeexpires,ortheoutputisresetfromthekeypadUserMenu.
PULSE-Theoutputalternatesonesecondonandonesecondoffuntiltheareais
disarmed,anoutputcutofftimeexpires,ortheoutputisresetfromthekeypadUser
Menu.
MOMENTARY-Theoutputisturnedononlyonceforonesecond.
FOLLOW-Theoutputisturnedonandremainsonwhilethezoneisinanoff,normalor
badcondition.Whenthezonerestores,theoutputisturnedoff.
AfteryouhaveselectedtheMessageToTransmit,thedisplaypromptsyouforthesame
threeselectionsforDisarmedShort,ArmedOpen,andArmedShortconditions.Ifthe
zoneisa24-hourtype,onlytheArmedOpenandArmedShortconditionsaredisplayed.
Whenyouhaveprogrammedallofthezoneconditions,theSwingerBypassselectionis
then dis played.
14.14 Swinger Bypass
SelectingYESallowsthezonetobeswingerbypassedbythecommunicator according
totheprogramminginSwingerBypassTripsandResetSwingerBypass.SelectingNO
disables swinger bypassing for this zone.
How it works
Ifwithinonehour,azonetripsthetotalnumberoftimesasspeciedinSwingerBypass
Trips, the communicatorbypassesituntilthefollowingconditionsoccur;theareain
which the zone is assigned is disarmed, the zone is manually reset through the Bypass
ZoneskeypadUserMenufunction,thezoneremainsnormalforonehourandtheReset
SwingerBypassisYES.
Ifthezonetripsfewerthanthespeciedtimeswithinonehourofthersttrip,the
bypasstripcounterreturnsto0(zero)andtheprocessmustberepeated.
AreportoftheswingerbypassissenttothereceiverifBypassReportsisYES.
14.15 Cross Zone
SelectYEStoenablecross-zoningforthiszone.Cross-zoningrequiresthiszonetotrip
twice, or this zone and another cross-zoned zone to trip, within a programmed time
before an alarm report is sent to the receiver. To operate correctly, all cross-zone zones
need to be programmed as the same zone type.
Whenacross-zonedzonetrips,theOutputactionassignedtothezoneactivates.The
cross-zonetimespeciedinSystemOptionsbeginstocountdown.SeetheCross-Zone
Timesection.Ifanothercross-zonedzoneinthesystemfaults,oriftherstzone
restores and faults again before the cross-zone time expires, the bell turns on and the
communicator sends an alarm report.
If no other cross-zone zone in the system trips before the cross-zone time expires, the
communicatorsendsonlyafaultreportfromtherstzonetothereceiver.
Note:IfCRSZONEisYES,avalidCRSZNTIMEmustbeprogrammedforthisfeatureto
be enabled.
14.16 Receiver Routing
ThisoptiondisplaysifZoneTypeissetforAuxiliary1orAuxiliary2.
PressanytoprowkeytoselecttheReceiverRoutingfortheselectedzone.
SelectNORMtosendAlarmandSupv/Trblmessagesfromthiszonetoreceiver1or
receiver2asprogrammedwithinthereceiverinCommunications.
Select1tosendAlarmandSupv/Trblmessagesfromthiszonetoreceiver1only,
regardless of the programming for the receiver in Communications.
Select2tosendAlarmandSupv/Trblmessagesfromthiszonetoreceiver2only,
regardless of the programming for that receiver in Communications.
SelectBOTHtosendAlarmandSupv/Trblmessagesfromthiszonetobothreceivers,
regardless of the programming for either receiver in Communications.
14.17 Zone Number
Enterthezonenumberyouwanttoprogramnext.ReturntoZoneInformationand
follow the descriptions of each programming prompt. If all zones are programmed, press
theARROWkeyattheZONENO:–displaytocontinue.
OUTPUT NO: 0
ACTION:
STD PLS MOM FLW
SWGR BYP NO YES
CRS ZONE NO YES
RECEIVER ROUTING
NORMAL
NORM 1 2 BOTH
ZONE NO: -