Appendix
Z-Wave Test Option
This feature allows the installer to test
CellComSL
CZcommunicationwithZ-Wave
devices.Asuccessfultestindicatesaresponsefromadevice.PressanytoprowSelect
keytoviewtheZ-WaveDeviceList.
PressCOMMANDtoadvancethrougheachZ-WavedeviceandpressanytoprowSelect
keytobeginthetestonthedevicedisplayed.
The name of the device displays above the device number. The current number of
successful communications followed by the total number of attempts displays to the
rightofthedevicenumber.Theteststopsafter99attempts.
PressCOMMANDtoviewthenalnumberofsuccessfulcommunications.
Contact ID Recvd
ThisdisplaysDTMFdigitsdialedfromtheburglarycontrolpanel.
Exiting the Diagnostics program
PresstheCOMMANDkeyuntilSTOPdisplays.PressanySelectkey.ThekeypadreturnstotheStatusListdisplay.
18.3 Using the 984 Command Function
WhennotintheProgrammingMenu,thefunction984+COMMANDcanbeenteredatthekeypad,andaremote
options menu appears. This menu contains the following options:
CELL
Thecommunicatorallowsyoutoperformatestoneachcomponentofthecellularcommunicationpaths.While
theStatusListdisplays,enter984andpresstheCOMMANDkey.PresstheSelectkeyunder CELL to allow the
communicatortoperformaCommunicationStatusTest.ThekeypaddisplaysCELL IS BUSY if the modem is being
testedfromanotherkeypad.
UponentryofaCellularpathwhenprompted,thetestrunsandtheresultsdisplayonthekeypadintheorder
theyweretested:MODEMOPERATING,IDENTIFIED,TOWERDETECTED,REGISTERED,CONNECTSUCCESS,andCELL
COMGOOD.PressCOMMANDtoadvancethroughtheresults.Whenthetestiscompleteyouarereturnedtothe
StatusList.SeetheDiagnosticFunctionssectionforadescriptionoftheCellularStatusresults.
18.4 Using the Walk Test
Thecommunicatorprovidesawalktestfeaturethatallowsasingletechniciantotestallthezonesonthe
system.ConducttheWalkTestwithin30minutesofresettingthecommunicator.TheWalkTestautomatically
endsifnozonesaretrippedfor20minutes.TEST IN PROGRESSdisplaysatallkeypads.Whenveminutes
remain, TEST END WARNINGdisplays.IfanyareasarearmedtheWalkTestdoesnotstartandSYSTEM ARMED
displays.
Walk Test
ToconducttheWalkTest,resetthecommunicatorbymomentarilypressingtheRESET
button.Fromthekeypad,enterthecode8144.ThekeypaddisplaysWALK TEST. If
thesystemismonitored,thesystemsendsaSystemTestBeginreporttotheCentral
Station.Allprogrammedzonesareincludedinthetest.
Trip Counter for Walk Test (STD)
DisplaysthenumberofzonetripsduringtheWalkTest.
• Eachtimeaselectedzonetrips,thekeypadbuzzes.
END - PresstheSelectkeydirectlybelowENDtostoptheWalkTest.WhentheWalkTest
endsora20minutetime-outexpires,analSensorResetoccurs.TheSystemTestEnd
message is sent to the receiver along with Verify and Fail messages for each zone under
test.Faultedzonesthendisplayonthekeypad.
Test End Warning
Whennozoneshavebeentrippedandveminutesremainonthe20minuteWalkTest
timer,thekeypaddisplaysTESTENDWARNINGandthekeypadtones.Ifnoadditional
testzonetripsoccur,thetestendsandanalSensorResetautomaticallyoccurs.The
SystemTestEndmessageissenttothereceiveralongwithVerifyandFailmessagesfor
eachzoneunderWALKtest.Faultedzonesthendisplayonthekeypad.
Failed Zones Display
EachzonethatdidnottripatleastonceduringtheWalkTestdisplaysonthekeypad
thatinitiatedthetest.AnyPanic(PN)orSupervisory(SV)24-hourzonethatisfaulted
attheendoftheWalkTestdisplaysatroubleconditionforthatzoneregardlessofthe
message programmed for the open or short condition of the zone and a zone trouble is
senttothereceiver.PresstheCOMMANDkeytodisplaythenextfailedzone.
TEST ZWAVE
DEVICE LIST:
HALLWAY LIGHT
HALLWAY LIGHT
LIGHT 02 0/0
HALLWAY LIGHT
99/99 SUCCESSFUL
WALK TEST
WALK TEST
TRIPS: XXX END
TEST END WARNING
SOUTH LOBBY
ZONE: 10 -FAIL