User's Manual
Digital Monitoring Products
CellComSL
Series Universal Communicator Installation and Programming Guide
32
Appendix
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
+ +
-
HI
HI
HI
LO
LO
LO
LO
HI
HI
LO
LO
HI
HI
LO
LO
HI
TIP
(BROWN)
RING
(GRAY )
TIP
(GREEN)
RING
(RED)
+
-
BLACK
RED
SYNC
COM
DATA
(USE SA4120XM-1
CABLE)
1 2 3 4 5 6 7 8
OUT 17
+12 AUX
GND
OUT 18
VISTA 20P ONLY
Ademco
Vista 20P
RB
J8
S3
J9
RESET
LOAD
S1
S2
J19
J26
Figure 19: Ademco Vista 20P ECP to CellComSL
18.12 Ademco Vista 20P ECP to CellComSL
18.11 Programming for Ademco Vista 20P ECP to CellComSL
ThefollowingstepsdescribehowtocongureAdemco/Honeywell control panels to accept arm and disarm commands
from a CellComSLusingthepanelECPBus.SeeFigure19:AdemcoVista20PtoCellComSLforpanelwiring.
1. ProgramPosition*29:Enter1.
2. ProgramPosition*43:EnterAccountNumber.
3. ProgramPosition*49:Enter5.
4. ProgramPosition*54:Enter0.
5. ProgramPosition*55:Enter1.
6. ProgramPosition*65:Enter1.
7. ProgramPosition*66:Enter1,1.
8. ProgramPosition*193:Enter10
AftercompletingprogrammingintheAdemco/Honeywellcontrolpanel,ECPmustbeenabledintheCellComSL.See
SystemOptions,KeypadInputforadditionalinformation.