User's Manual
CellComSL
Series Universal Communicator Installation and Programming Guide Digital Monitoring Products
1
IntroductIon
CellComSL™ Series Universal Alarm Communicator
Description
The
CellComSL
™SeriesAlarmCommunicatorprovidesafullysupervisedalarmcommunicationpathforany
burglaryorresidentialrecontrolpanel.TheCellComSLSeriescanbeconnectedtoacontrolpanel’sdialer
outputandusedtocaptureContactIDmessagesbased on SIA DC-05-1999.09-DCS.TheCellComSLChasa
built-inCDMAcellularmoduletosendmessagestoDMPModelSCS-1RorSCS-VRCentralStationReceivers.The
c
ommunicator also provides four input zones and two open-collector outputs for connection to burglary or
residentialrecontrolpaneloutputsandzones.TheCellComSLSeriesCommunicatorZone4allowsaconnection
to the bell output of an existing burglary control panel. The communicator operates in a variety of applications:
CIDDialerConnection,Zones1-4InputConnections,orZone4BellConnection(SeeApplicationsonpage5).The
CellComSL
CZ™AlarmCommunicatorincludesanonboardZ-Wavecontrollerforhomeautomationapplications.
What is Included
The
CellComSL
SeriesUniversalAlarmCommunicatorincludesthefollowing:
• PCBwithEnclosure
• 3.7Vdc800mAhLithiumIonSystemBattery
• HardwarePack
System Components
1.1 Terminals (J9)
Power Connection Terminals
PowerisprovidedfromtheNominal12Vdcauxiliaryoutputoftheburglarycontrolpanel.
OBSERVEPOLARITY(SeeFigure1andBacklitLogo)
Using18-22AWGwire,connectthe
communicator
terminal+12tothepositiveterminalonthe
control panel
auxiliary output
.
ConnectthecommunicatorterminalG(Ground)tothenegativeterminalonthecontrolpanelauxiliaryoutput.
Control Panel Standby Power
Duringapoweroutage,theCellComSLdrawspowerfromthecontrolpanel’sbackupbattery.TheCellComSLmust
be included in the standby battery calculations for the control panel.
Zones 1-4
TerminalsZ1toZ3,G(Ground),Z4+andZ4-providefourzonestoconnecttoindividualrelayoutputson
thecontrolpanel.Zone4(Z4+andZ4-)canbeconnectedtothecontrolpanelbelloutput.SeeZone4Bell
Connection.
Open-Collector Outputs
Thetwooutputs,terminalsO1andO2(seeFigure1),canbeprogrammedtoindicatetheactivityofthezones
Figure 1: CellComSL Series Communicator
RB
J8
S3
J9
RESET
LOAD
S1
S2
J19
J26
system components