User's Manual

Digital Monitoring Products
CellComSL
Series Universal Communicator Installation and Programming Guide
2
system components
orconditionsoccurringonthesystem.Open-Collectoroutputsdonotprovideavoltagebutinsteadswitch-to-
groundthevoltagefromanothersource.Maximumvoltageis30Vdc@50mA.Theoutputscanrespondtoanyof
the conditions listed below:
1. Activationbyzonecondition:Steady,Pulse,Momentary,orFollow
2. Communication
3. Armedareaannunciation
4. RemoteArmingOutput
Dialer Connection
Directlyconnectthetelcophoneline(tipandring)fromthecontrolpaneltotheCellComSLSeriesUniversal
CommunicatorterminalR(Ring)andoneintoT(Tip)(SeeCIDDialerConnection).
1.2 System Battery Connection (BAT)
Installation Safety
Ground Yourself Before Handling the Communicator! To discharge static, touch any grounded metal, such
as the control panel enclosure, before touching the communicator.
System Battery
The system battery is used for internal and cellular operations and is not a standby battery.
Ifthesystembatteryislow,ornotpluggedintotheBATbatteryconnector,alowbatteryconditionisindicated
by the
communicator
.SeeBacklitLogoSectionintheAppendix.
PlugintheinternallithiumsystembatteryintheBATconnector.Use9000BAT.
DMPrecommendsreplacingthebatteryevery3yearsundernormaluse.
Usethefollowingstepstoreplacethesystembattery.
1. UnplugthebatteryBATconnectorfromthecommunicator.
2. LoosenthetopPCBsnaps.
3. LeanthecommunicatorPCBforwardandliftoutfromthebottomPCBsnaps.
4 Removeandproperlydisposeoftheusedbattery.
Caution:Riskofre,explosion,andburns.Donotdisassemble,heatabove212°F(100°C),orincinerate.
Properly dispose of used batteries.
5. Place the new battery into the housing base with the battery wires directed toward the bottom left corner.
SeeFigure2.
6. SetthePCBintothebottomsnapsandpressintothetopsnapstosecureinplace.
7. PlugthebatteryintotheBATconnector.
Note:Ifremovingthecommunicatorfromservice,disconnectthesystembatteryfromtheBATconnector.
1.3 Programming Connection
A4-pinheader(PROG)isprovidedtoconnectakeypadwhenusingaDMP
Model330ProgrammingCable.Thisprovidesaquickandeasyconnection
for programming the
CellComSL
SeriesUniversalAlarmCommunicator.After
programmingiscomplete,removethekeypad.
Top PCB Snaps
Bottom PCB Snaps
Battery
connector
3.7 Vdc
800 mAH Lithium
Ion Battery
Figure 2: Replacement System Battery Location
RB
J8
S3
J9
RESET
LOAD
S1
S2
J19
J26
Figure 3: PROG Port Location