User's Manual
iComSL
Series Universal Communicator Installation and Programming Guide Digital Monitoring Products
15
Remote Options
9.1 Remote Options
This section allows you to enter the information needed for Remote Command/Remote
Programmingoperation.AdescriptionoftheRemoteOptionsfollows:
9.2 Remote Key
This option allows you to enter a code of up to eight digits for use in verifying the
authority of a receiver to perform a remote command/programming session. The
receivermustgivethecorrectkeytothe
c
ommunicator before being allowed access.
All
iComSL
CommunicatorsareshippedfromthefactorywiththeRemoteKeypresetas
blank.
ToenteranewRemoteKey,pressanySelectkeyandenteranycombinationofupto8
digits.Thenumbersyouenterappearasasterisks.PressCOMMAND.
9.3 Remote Disarm
EnterYEStoenablethe
c
ommunicatortobedisarmedremotely.SelectingNOdisables
remote disarming.
System Reports
10.1 System Reports
This function allows you to select which reports the
c
ommunicator sends to the receiver.
10.2 Opening/Closing Reports
NO-NoOpening/ClosingReportsaresent.
YES-SendsOpening/ClosingReportsforeachprogrammedarea.
10.3 Zone Restoral Reports
This option allows you to specify whether the communicator sends zone restoral reports
and when they will be sent.
NO-Restoralreportsarenotsentbythecommunicator.
YES-Thecommunicator
always sends zone restoral reports at the time the zone
restores from an alarm or trouble condition.
DISARM-Thecommunicator sends zone restoral reports when a zone that has
restored from an alarm or trouble is disarmed. Twenty-four hour zones send restorals
immediately.
System Options
11.1 System Options
This section allows you to select system wide parameters used in the operation of the
c
ommunicator system.AdescriptionofeachSystemOptionfollows:
11.2 Entry Delay 1
Entertheentrydelaytimeforallexittypezonesprogrammed.WhenanarmedExittype
zone is faulted, the area must be disarmed before the entry delay expires or a fault will
bedetected.AllBurglarytypezonesaredelayedalongwiththeExitzone.Entrydelay
timescanbefrom30to250seconds.Defaultis30seconds.
11.3 Exit Delay
EntertheExitDelaytimeforallExittypezones.Whentheexitdelaytimestarts,all
activityonexitandburglaryzonesisignoreduntiltheexitdelayexpires.DuringExit
Delay,ifanexitzonetrips,thenrestores,andtripsagain,theExitDelaytimerrestarts.
Thisrestartcanoccuronlyonce.Exitdelaytimescanbefrom30to250seconds.
Defaultis60seconds.
ExitErrorOperation:Atarming,whenanentry/exitzone(EX)isfaultedattheendof
theexitdelaythenazonealarmandanExitErroraresenttothereceiver.
11.4 Cross Zone Time
Enterthetimeallowedbetweenzonefaults.Whenazoneprogrammedforcrosszoning
faults, the
c
ommunicatorbeginscountingdowntheCross-ZoneTimeenteredhere.Ifthe
same zone or another cross-zoned zone faults within this time, an alarm report is sent to
the receiver.
IftheCross-ZoneTimeexpireswithoutthesecondzonefault,onlyazonefaultreport
fromtherstzoneissenttothereceiver.TheCross-ZoneTimecanbefrom4to250
secondsinonesecondincrements.Enter0(zero)todisabletheCross-ZoneTime
feature.SeetheAppendix-CrossZoning.
REMOTE OPTIONS
RMT KEY:
DISARM NO YES
SYSTEM REPORTS
O/C RPTS NO YES
RESTORAL YES
NO YES DISARM
SYSTEM OPTIONS
ENTRY DLY 1: 30
EXIT DELAY: 60
CRS ZONE TM: 0
remote optIons
system reports
system optIons