User's Guide
Table Of Contents
- Panel Specifications
- Introduction
- System Components
- Installation
- Primary Power Supply
- Secondary Power Supply
- LED Operation
- RESET Button
- TAMPER Button
- PROG Programming Connection
- On-Board 1100 Series Wireless
- Wireless Zones
- Wireless Key Fobs and Outputs
- Flash LOAD Button
- On-Board Z-Wave Connection
- On-Board Wi-Fi Network
- Cellular Connection
- Wireless Keypads
- Programming Introduction
- Initialization
- Fast Programming
- Communication
- 22.1 Communication
- 22.2 Account Number
- 22.3 Transmission Delay
- 22.4 Communication Type
- 22.5 Backup Cellular
- 22.6 Test Time
- 22.7 Test Days
- 22.8 Check In Minutes
- 22.9 Fail Time
- 22.10 Send Communication Trouble
- 22.11 First Cell APN
- 22.12 Second Cell APN
- 22.13 Receiver 1 Programming
- 22.14 Alarm Reports
- 22.15 Supervisory/Trouble Reports
- 22.16 Opening/Closing and User Reports
- 22.17 Test Report
- 22.18 First IP Address
- 22.19 First IP Port
- 22.20 Second IP Address
- 22.21 Second IP Port
- 22.22 Receiver 2 Programming
- 22.23 Alarm Reports
- 22.24 Supervisory/Trouble Reports
- 22.25 Opening/Closing and User Reports
- 22.26 Test Report
- 22.27 First IP Address
- 22.28 First IP Port
- 22.29 Second IP Address
- 22.30 Second IP Port
- 22.1 Communication
- Network Options
- Messaging Setup
- Device Setup
- Remote Options
- System Reports
- System Options
- 28.1 System Options
- 28.2 System
- 28.3 Closing Code
- 28.4 Closing Check
- 28.5 Entry Delay 1
- 28.6 Exit Delay
- 28.7 Cross Zone Time
- 28.8 Power Fail Delay
- 28.9 Swinger Bypass Trips
- 28.10 Reset Swinger Bypass
- 28.11 Zone Activity Hours
- 28.12 Arm Activity Days
- 28.13 Time Zone Changes
- 28.14 Time Display
- 28.15 House Code
- 28.15.1 Detect Wireless Jamming
- 28.15.2 Wireless Audible Annunciation
- 28.16 Enable Keypad Panic Keys
- 28.17 Occupied Premises
- 28.18 Use False Alarm Question
- 28.19 Weather Zip Code
- 28.1 System Options
- Bell Options
- Output Options
- Output Setup
- Area Information
- Zone Information
- 33.1 Zone Information
- 33.2 Zone Number
- 33.3 Key Fob
- 33.4 Zone Name
- 33.5 Zone Type
- 33.6 Arming Zone Assignment
- 33.7 Area Assignment
- 33.7.1 Style
- 33.8 DMP Wireless
- 33.8.1 Serial Number Entry
- 33.8.2 Contact
- 33.8.3 Supervision Time
- 33.8.4 LED Operation
- 33.8.5 Disarm/Disable
- 33.8.6 Wireless PIR Pulse Count
- 33.8.7 Wireless PIR Sensitivity
- 33.8.8 Next Zone
- 33.9 1144 Series Key Fobs
- 33.9.1 Key Fob User Number
- 33.9.2 Key Fob Serial Number
- 33.9.3 Key Fob Supervision Time
- 33.9.4 Number of Key Fob Buttons
- 33.9.5 Key Fob Button Selection (Four Buttons)
- 33.9.6 Key Fob Button Selection (Two Buttons)
- 33.9.7 Button Action
- 33.9.8 Button Press Time
- 33.9.9 Arm/Disarm Area Selection
- 33.9.10 Output Number
- 33.9.11 Output Action
- 33.10 Alarm Action
- 33.11 Disarmed Open
- 33.11.1 Message To Transmit
- 33.11.2 Output Number
- 33.11.3 Output Action
- 33.12 Swinger Bypass
- 33.13 Prewarn Address
- 33.14 Entry Delay
- 33.15 Cross Zone
- 33.16 Priority
- 33.17 Traffic Count
- 33.18 Zone Audit Days
- 33.19 Receiver Routing
- 33.20 Zone Number
- 33.1 Zone Information
- Stop
- Set Lockout Code
- Appendix
- Listed Compliance Specifications
- Household Burglar-Alarm System Units ANSI/UL 1023
- Central Station Burglar Alarm Units ANSI/UL 1610
- Household Fire Warning System ANSI/UL 985 NFPA 72 Specifications
- False Alarm Reduction Programmable Options ANSI/SIA CP-01-2010
- Revisions to This Document
- Certifications
- Ordering Information
- Accessories
XTLplus Installation and Programming Guide Digital Monitoring Products
3
INSTALLATION
Installation
4.1 Mounting Location Information
A location should be selected that is centrally located between the 1100 Series transmitters used in the
installation. Install the XTLplus away from metal objects. Mounting the panel on or near metal surfaces
impairs performance. When selecting the proper mounting location of a transmitter, refer to the LED Survey
Operation section of the specic installation guide for the transmitter being installed.
4.2 Mounting the Enclosure
The enclosure for the panel must be mounted using the provided #6 screws in the four mounting holes shown
in Figure 1. Mount the enclosure in a secure, dry place away from metal objects to protect the panel from
damage due to tampering or the elements. Mount the panel a minimum of 4 feet from any wireless
transmitters or repeaters. It is not necessary to remove the PCB when installing the enclosure.
Figure 1: Mounting Hole Locations
Primary Power Supply
5.1 DC Input
Mount the panel near a wall outlet for the Model 372-500-W plug-in DC power supply. In addition to powering
the panel, the DC plug-in power supply also charges the back-up battery. The 372-500-W must be located
within 100 feet of the panel using 22 AWG wire. Use the following steps to connect the plug-in power supply:
OBSERVE POLARITY
1. Using 22 AWG wire, connect the panel DC terminal (+) to the positive terminal on the power supply.
2. Connect the panel DC terminal (-) to the negative terminal on the power supply. See Figure 2.
3. Plug the power supply into a 120 Volt AC, 60Hz dedicated outlet not controlled by a switch.
Figure 2: DC Power Supply Connection
Mounting Hole Locations
ZWave
Module
WiFi
Antenna
RESETLOAD
BAT
PROG
R B
+ DC -
S
N
LEV
LPC-0181
R1
INSTALL GUIDE
LT-1434
CELL
MODULE
©
2015 DMP
WWW.DMP.COM
Wire Exits for DC
Power Supply
+
Model 372-500-W
DC Plug-in
Power Supply
Use 22 AWG for
Power Supply connection
_
RESETLOAD
BAT
PROG
R B
+ DC -
S
N
LEV
LPC-0181
R1
INSTALL GUIDE
LT-1434
CELL
MODULE
©
2015 DMP
WWW.DMP.COM