User's Guide
Table Of Contents
- Panel Specifications
- Introduction
- System Components
- Installation
- Primary Power Supply
- Secondary Power Supply
- LED Operation
- RESET Button
- TAMPER Button
- PROG Programming Connection
- On-Board 1100 Series Wireless
- Wireless Zones
- Wireless Key Fobs and Outputs
- Flash LOAD Button
- On-Board Z-Wave Connection
- On-Board Wi-Fi Network
- Cellular Connection
- Wireless Keypads
- Programming Introduction
- Initialization
- Fast Programming
- Communication
- 22.1 Communication
- 22.2 Account Number
- 22.3 Transmission Delay
- 22.4 Communication Type
- 22.5 Backup Cellular
- 22.6 Test Time
- 22.7 Test Days
- 22.8 Check In Minutes
- 22.9 Fail Time
- 22.10 Send Communication Trouble
- 22.11 First Cell APN
- 22.12 Second Cell APN
- 22.13 Receiver 1 Programming
- 22.14 Alarm Reports
- 22.15 Supervisory/Trouble Reports
- 22.16 Opening/Closing and User Reports
- 22.17 Test Report
- 22.18 First IP Address
- 22.19 First IP Port
- 22.20 Second IP Address
- 22.21 Second IP Port
- 22.22 Receiver 2 Programming
- 22.23 Alarm Reports
- 22.24 Supervisory/Trouble Reports
- 22.25 Opening/Closing and User Reports
- 22.26 Test Report
- 22.27 First IP Address
- 22.28 First IP Port
- 22.29 Second IP Address
- 22.30 Second IP Port
- 22.1 Communication
- Network Options
- Messaging Setup
- Device Setup
- Remote Options
- System Reports
- System Options
- 28.1 System Options
- 28.2 System
- 28.3 Closing Code
- 28.4 Closing Check
- 28.5 Entry Delay 1
- 28.6 Exit Delay
- 28.7 Cross Zone Time
- 28.8 Power Fail Delay
- 28.9 Swinger Bypass Trips
- 28.10 Reset Swinger Bypass
- 28.11 Zone Activity Hours
- 28.12 Arm Activity Days
- 28.13 Time Zone Changes
- 28.14 Time Display
- 28.15 House Code
- 28.15.1 Detect Wireless Jamming
- 28.15.2 Wireless Audible Annunciation
- 28.16 Enable Keypad Panic Keys
- 28.17 Occupied Premises
- 28.18 Use False Alarm Question
- 28.19 Weather Zip Code
- 28.1 System Options
- Bell Options
- Output Options
- Output Setup
- Area Information
- Zone Information
- 33.1 Zone Information
- 33.2 Zone Number
- 33.3 Key Fob
- 33.4 Zone Name
- 33.5 Zone Type
- 33.6 Arming Zone Assignment
- 33.7 Area Assignment
- 33.7.1 Style
- 33.8 DMP Wireless
- 33.8.1 Serial Number Entry
- 33.8.2 Contact
- 33.8.3 Supervision Time
- 33.8.4 LED Operation
- 33.8.5 Disarm/Disable
- 33.8.6 Wireless PIR Pulse Count
- 33.8.7 Wireless PIR Sensitivity
- 33.8.8 Next Zone
- 33.9 1144 Series Key Fobs
- 33.9.1 Key Fob User Number
- 33.9.2 Key Fob Serial Number
- 33.9.3 Key Fob Supervision Time
- 33.9.4 Number of Key Fob Buttons
- 33.9.5 Key Fob Button Selection (Four Buttons)
- 33.9.6 Key Fob Button Selection (Two Buttons)
- 33.9.7 Button Action
- 33.9.8 Button Press Time
- 33.9.9 Arm/Disarm Area Selection
- 33.9.10 Output Number
- 33.9.11 Output Action
- 33.10 Alarm Action
- 33.11 Disarmed Open
- 33.11.1 Message To Transmit
- 33.11.2 Output Number
- 33.11.3 Output Action
- 33.12 Swinger Bypass
- 33.13 Prewarn Address
- 33.14 Entry Delay
- 33.15 Cross Zone
- 33.16 Priority
- 33.17 Traffic Count
- 33.18 Zone Audit Days
- 33.19 Receiver Routing
- 33.20 Zone Number
- 33.1 Zone Information
- Stop
- Set Lockout Code
- Appendix
- Listed Compliance Specifications
- Household Burglar-Alarm System Units ANSI/UL 1023
- Central Station Burglar Alarm Units ANSI/UL 1610
- Household Fire Warning System ANSI/UL 985 NFPA 72 Specifications
- False Alarm Reduction Programmable Options ANSI/SIA CP-01-2010
- Revisions to This Document
- Certifications
- Ordering Information
- Accessories
Digital Monitoring Products XTLplus Installation and Programming Guide
30
AREA INFORMATION
until the expiration of a 10-minute Closing Check delay. If the area has been
disarmed outside a schedule, the Closing Check delay occurs one hour after the
area is disarmed.
At arming, faulted zones are handled according to the option selected in Bad
Zones. If a Closing report is sent, the user number is indicated as SCH on the SCS-
1R Receiver. Select NO to disable automatic arming for this area. Default is NO.
32.4.1 Bad Zones
At the time of automatic arming, some zones in the area may not be in a normal
condition. This option allows you to program the panel’s response to these bad
zones. This option is not displayed if AUTO ARM is NO.
BYP - All bad zones are bypassed. A report of the bypass is sent to the receiver
if Bypass Reports has been selected as YES. See the Bypass Reports section. The
report indicates SCH as the user number.
FORC - All bad zones are force armed. Zones force armed in a bad condition are
capable of restoring into the system and reporting alarms if tripped. A report of
the force arm is sent if Bypass Reports is YES. See the Bypass Reports section. The
report indicates the user number as SCH.
REF - The automatic arming is refused and no arming takes place. A No Closing
report is sent to the receiver regardless of the Closing Check selection.
Note: For listed installations, set Bad Zones to REF.
32.5 Automatic Disarming
NO disables automatic disarming by schedule for this area. Select YES to allow this
area to automatically disarm according to a schedule. If an Opening report is sent
to the receiver, the user number is indicated as SCH.
Zone Information
33.1 Zone Information
This allows you to dene the operation of each protection zone used in the system.
33.2 Zone Number
Zone numbers on the XTLplus panel default to the following settings. The settings
can be changed as described in the following sections. Zones 51-54 can be wireless
zones, key fobs or slow outputs. Zones 61-64 can be wireless zones, key fobs, or
fast outputs.
Zone Number Zone Name Zone Type Area Assignment
1
FRONT DOOR EX PERIM
2
BACK DOOR EX PERIM
3
GARAGE ENTRY DR NT INT
4
PATIO DOOR EX PERIM
5
BASEMENT DOOR EX PERIM
6
GARAGE DOOR EX PERIM
7
WAREHOUSE DOOR EX PERIM
8
SHIPPING DOOR EX PERIM
9
BREAKROOM DOOR NT INT
10
STOCKROOM DOOR NT INT
11
FRONT MOTION NT INT
12
BACK MOTION NT INT
13
HALLWAY MOTION NT INT
14
UPSTAIRS MOTION NT INT
15
BASEMENT MOTION NT INT
16
GARAGE MOTION NT INT
17
GLASSBREAK NT INT
18
WATER DETECTOR AUX 1 INT
19
LOW TEMPERATURE AUX 1 INT
20
SMOKE DETECTOR FI PERIM
21
FRONT SMOKE FI PERIM
22
BACK SMOKE FI PERIM
23
HALLWAY SMOKE FI PERIM
24
UPSTAIRS SMOKE FI PERIM
25
BASEMENT SMOKE FI PERIM
26
OFFICE SMOKE FI PERIM
27
WAREHOUSE SMOKE FI PERIM
BADZONES: BYP
BYP FORC REF
AUTODIS NO YES
ZONEINFORMATION
ZONENO:-
ZONE INFORMATION










