User's Guide
Table Of Contents
- Panel Specifications
- Introduction
- System Components
- Installation
- Primary Power Supply
- Secondary Power Supply
- LED Operation
- RESET Button
- TAMPER Button
- PROG Programming Connection
- On-Board 1100 Series Wireless
- Wireless Zones
- Wireless Key Fobs and Outputs
- Flash LOAD Button
- On-Board Z-Wave Connection
- On-Board Wi-Fi Network
- Cellular Connection
- Wireless Keypads
- Programming Introduction
- Initialization
- Fast Programming
- Communication
- 22.1 Communication
- 22.2 Account Number
- 22.3 Transmission Delay
- 22.4 Communication Type
- 22.5 Backup Cellular
- 22.6 Test Time
- 22.7 Test Days
- 22.8 Check In Minutes
- 22.9 Fail Time
- 22.10 Send Communication Trouble
- 22.11 First Cell APN
- 22.12 Second Cell APN
- 22.13 Receiver 1 Programming
- 22.14 Alarm Reports
- 22.15 Supervisory/Trouble Reports
- 22.16 Opening/Closing and User Reports
- 22.17 Test Report
- 22.18 First IP Address
- 22.19 First IP Port
- 22.20 Second IP Address
- 22.21 Second IP Port
- 22.22 Receiver 2 Programming
- 22.23 Alarm Reports
- 22.24 Supervisory/Trouble Reports
- 22.25 Opening/Closing and User Reports
- 22.26 Test Report
- 22.27 First IP Address
- 22.28 First IP Port
- 22.29 Second IP Address
- 22.30 Second IP Port
- 22.1 Communication
- Network Options
- Messaging Setup
- Device Setup
- Remote Options
- System Reports
- System Options
- 28.1 System Options
- 28.2 System
- 28.3 Closing Code
- 28.4 Closing Check
- 28.5 Entry Delay 1
- 28.6 Exit Delay
- 28.7 Cross Zone Time
- 28.8 Power Fail Delay
- 28.9 Swinger Bypass Trips
- 28.10 Reset Swinger Bypass
- 28.11 Zone Activity Hours
- 28.12 Arm Activity Days
- 28.13 Time Zone Changes
- 28.14 Time Display
- 28.15 House Code
- 28.15.1 Detect Wireless Jamming
- 28.15.2 Wireless Audible Annunciation
- 28.16 Enable Keypad Panic Keys
- 28.17 Occupied Premises
- 28.18 Use False Alarm Question
- 28.19 Weather Zip Code
- 28.1 System Options
- Bell Options
- Output Options
- Output Setup
- Area Information
- Zone Information
- 33.1 Zone Information
- 33.2 Zone Number
- 33.3 Key Fob
- 33.4 Zone Name
- 33.5 Zone Type
- 33.6 Arming Zone Assignment
- 33.7 Area Assignment
- 33.7.1 Style
- 33.8 DMP Wireless
- 33.8.1 Serial Number Entry
- 33.8.2 Contact
- 33.8.3 Supervision Time
- 33.8.4 LED Operation
- 33.8.5 Disarm/Disable
- 33.8.6 Wireless PIR Pulse Count
- 33.8.7 Wireless PIR Sensitivity
- 33.8.8 Next Zone
- 33.9 1144 Series Key Fobs
- 33.9.1 Key Fob User Number
- 33.9.2 Key Fob Serial Number
- 33.9.3 Key Fob Supervision Time
- 33.9.4 Number of Key Fob Buttons
- 33.9.5 Key Fob Button Selection (Four Buttons)
- 33.9.6 Key Fob Button Selection (Two Buttons)
- 33.9.7 Button Action
- 33.9.8 Button Press Time
- 33.9.9 Arm/Disarm Area Selection
- 33.9.10 Output Number
- 33.9.11 Output Action
- 33.10 Alarm Action
- 33.11 Disarmed Open
- 33.11.1 Message To Transmit
- 33.11.2 Output Number
- 33.11.3 Output Action
- 33.12 Swinger Bypass
- 33.13 Prewarn Address
- 33.14 Entry Delay
- 33.15 Cross Zone
- 33.16 Priority
- 33.17 Traffic Count
- 33.18 Zone Audit Days
- 33.19 Receiver Routing
- 33.20 Zone Number
- 33.1 Zone Information
- Stop
- Set Lockout Code
- Appendix
- Listed Compliance Specifications
- Household Burglar-Alarm System Units ANSI/UL 1023
- Central Station Burglar Alarm Units ANSI/UL 1610
- Household Fire Warning System ANSI/UL 985 NFPA 72 Specifications
- False Alarm Reduction Programmable Options ANSI/SIA CP-01-2010
- Revisions to This Document
- Certifications
- Ordering Information
- Accessories
XTLplus Installation and Programming Guide Digital Monitoring Products
31
ZONE INFORMATION
28
SHIPPING SMOKE FI PERIM
29
STORAGE SMOKE FI PERIM
30
SHED DOOR EX PERIM
31
SHOP DOOR EX PERIM
32
OFFICE DOOR NT PERIM
33
BREEZEWAY DOOR NT PERIM
34
SHOP WINDOW NT PERIM
35
OFFICE WINDOW NT PERIM
36
BREEZEWAY WINDOW NT PERIM
37
BASEMENT WINDOW NT PERIM
38
SHED MOTION NT PERIM
39
SHOP MOTION NT PERIM
40
OFFICE MOTION NT PERIM
41
BREEZEWAY MOTION NT PERIM
42
DRIVEWAY BEAM NT PERIM
43
CASHIER PANIC PN PERIM
44
OFFICE PANIC PN PERIM
45
CO DETECTOR FI PERIM
46
EMERGENCY PENDNT PN PERIM
47
GARAGE HEAT AUX 1 PERIM
48
UTILITY ROOM HT AUX 1 PERIM
51
OUTPUT 1 PERIM
52
OUTPUT 2 PERIM
53
OUTPUT 3 PERIM
54
OUTPUT 4 PERIM
61
ALARM SOUNDER 1 PERIM
62
ALARM SOUNDER 2 PERIM
63
ALARM SOUNDER 3 PERIM
64
ARM/ALARM/LIGHT PERIM
33.3 Key Fob
Select YES to program an 1144 Series Key Fob for zones 51-54 or 61-64.
When YES is selected, programming continues at the 1144 Series Key Fobs Section.
Default is NO.
33.4 Zone Name
Press any select key to display the default zone name. To change the default zone
name, press any select key to clear name. Enter up to 16 characters for the new
zone name. This name is displayed at the keypads when the zone is bad or viewed
in Display Events. The zone name is also sent to the receiver as part of a zone
event report.
A zone that is not part of the system must be marked *UNUSED*. To mark a zone
unused, de lete the old name by pressing any select key, then press the COMMAND
key. The pro grammer auto matically pro grams the name as * UNUSED *. If you
selected ZONES? NO YES to clear the panel’s memory during Initialization, the
zones will already be marked * UNUSED *. See the Initialization section.
33.5 Zone Type
The Zone Type denes the panel’s response to the zone being opened or shorted.
Refer to the Appendix for zone type defaults and descriptions.
Each zone has a default type. When you assign a Zone Type to a zone, responses
are made automatically for the zone. There are 11 Zone Types to choose from
including Blank. The func tional details of each response are described in Zone Type
Defaults in the Appendix.
To change the Zone Type, press any select key. The display lists the four Zone Types
shown below. When the Zone Type you want to select displays, press the select key
below the name.
Blank, Night, Day, or Exit. Press COMMAND to display additional zone types.
Fire, Panic, Emergency, or Supervisory. Press COMMAND to display additional zone
KEYFOB NO YES
*UNUSED*
ZONETYPE:-
FI PN EM SV
A1 A2 FV AR
-- NT DY EX










