User's Guide
Table Of Contents
- Panel Specifications
- Introduction
- System Components
- Installation
- Primary Power Supply
- Secondary Power Supply
- LED Operation
- RESET Button
- TAMPER Button
- PROG Programming Connection
- On-Board 1100 Series Wireless
- Wireless Zones
- Wireless Key Fobs and Outputs
- Flash LOAD Button
- On-Board Z-Wave Connection
- On-Board Wi-Fi Network
- Cellular Connection
- Wireless Keypads
- Programming Introduction
- Initialization
- Fast Programming
- Communication
- 22.1 Communication
- 22.2 Account Number
- 22.3 Transmission Delay
- 22.4 Communication Type
- 22.5 Backup Cellular
- 22.6 Test Time
- 22.7 Test Days
- 22.8 Check In Minutes
- 22.9 Fail Time
- 22.10 Send Communication Trouble
- 22.11 First Cell APN
- 22.12 Second Cell APN
- 22.13 Receiver 1 Programming
- 22.14 Alarm Reports
- 22.15 Supervisory/Trouble Reports
- 22.16 Opening/Closing and User Reports
- 22.17 Test Report
- 22.18 First IP Address
- 22.19 First IP Port
- 22.20 Second IP Address
- 22.21 Second IP Port
- 22.22 Receiver 2 Programming
- 22.23 Alarm Reports
- 22.24 Supervisory/Trouble Reports
- 22.25 Opening/Closing and User Reports
- 22.26 Test Report
- 22.27 First IP Address
- 22.28 First IP Port
- 22.29 Second IP Address
- 22.30 Second IP Port
- 22.1 Communication
- Network Options
- Messaging Setup
- Device Setup
- Remote Options
- System Reports
- System Options
- 28.1 System Options
- 28.2 System
- 28.3 Closing Code
- 28.4 Closing Check
- 28.5 Entry Delay 1
- 28.6 Exit Delay
- 28.7 Cross Zone Time
- 28.8 Power Fail Delay
- 28.9 Swinger Bypass Trips
- 28.10 Reset Swinger Bypass
- 28.11 Zone Activity Hours
- 28.12 Arm Activity Days
- 28.13 Time Zone Changes
- 28.14 Time Display
- 28.15 House Code
- 28.15.1 Detect Wireless Jamming
- 28.15.2 Wireless Audible Annunciation
- 28.16 Enable Keypad Panic Keys
- 28.17 Occupied Premises
- 28.18 Use False Alarm Question
- 28.19 Weather Zip Code
- 28.1 System Options
- Bell Options
- Output Options
- Output Setup
- Area Information
- Zone Information
- 33.1 Zone Information
- 33.2 Zone Number
- 33.3 Key Fob
- 33.4 Zone Name
- 33.5 Zone Type
- 33.6 Arming Zone Assignment
- 33.7 Area Assignment
- 33.7.1 Style
- 33.8 DMP Wireless
- 33.8.1 Serial Number Entry
- 33.8.2 Contact
- 33.8.3 Supervision Time
- 33.8.4 LED Operation
- 33.8.5 Disarm/Disable
- 33.8.6 Wireless PIR Pulse Count
- 33.8.7 Wireless PIR Sensitivity
- 33.8.8 Next Zone
- 33.9 1144 Series Key Fobs
- 33.9.1 Key Fob User Number
- 33.9.2 Key Fob Serial Number
- 33.9.3 Key Fob Supervision Time
- 33.9.4 Number of Key Fob Buttons
- 33.9.5 Key Fob Button Selection (Four Buttons)
- 33.9.6 Key Fob Button Selection (Two Buttons)
- 33.9.7 Button Action
- 33.9.8 Button Press Time
- 33.9.9 Arm/Disarm Area Selection
- 33.9.10 Output Number
- 33.9.11 Output Action
- 33.10 Alarm Action
- 33.11 Disarmed Open
- 33.11.1 Message To Transmit
- 33.11.2 Output Number
- 33.11.3 Output Action
- 33.12 Swinger Bypass
- 33.13 Prewarn Address
- 33.14 Entry Delay
- 33.15 Cross Zone
- 33.16 Priority
- 33.17 Traffic Count
- 33.18 Zone Audit Days
- 33.19 Receiver Routing
- 33.20 Zone Number
- 33.1 Zone Information
- Stop
- Set Lockout Code
- Appendix
- Listed Compliance Specifications
- Household Burglar-Alarm System Units ANSI/UL 1023
- Central Station Burglar Alarm Units ANSI/UL 1610
- Household Fire Warning System ANSI/UL 985 NFPA 72 Specifications
- False Alarm Reduction Programmable Options ANSI/SIA CP-01-2010
- Revisions to This Document
- Certifications
- Ordering Information
- Accessories
Digital Monitoring Products XTLplus Installation and Programming Guide
38
ZONE INFORMATION
the panel sends only a fault report from the rst zone to the receiver.
Note: If CRS ZONE is YES, a valid CRS ZN TIME must be programmed in System
Options for this feature to be enabled.
Cross-zoning is not compatible and cannot be enabled for Fire Verify
zone types.
33.16 Priority
Selecting YES allows you to provide additional protection for a zone by requiring it
to be in a normal condition before its assigned area can be armed. A priority zone
cannot be bypassed.
A Priority zone not in a normal condition cannot be armed. If a user attempts to
arm the area, the keypad displays the bad zone name followed by PRIORITY ZONE
and the arming is stopped.
33.17 Trafc Count
This option is displayed for NT or EX type zones. Select YES to provide reporting
to the receiver of the number of zone trips while in a disarmed state. The number
of trips for each zone set as trafc count are added together and included with
the area closing message and reported to the central station automation system.
Default is NO.
33.18 Zone Audit Days
Enter the number of days (0 to 99) allowed to elapse without the zone being
tripped before a fault message is sent. The message is sent to the receiver(s)
programmed to receive Supervisory/Trouble Reports at 10:00 am following the
expiration of the timer. Each time the zone is tripped, the Zone Audit Days timer
restarts and begins to countdown the number of days programmed. After the
countdown expires, a fault message is sent and the Zone Audit Days timer restarts
and begins to countdown the number of days programmed. Available for all zone
types except re and re verify. Enter 0 (zero) to disable this function. Default is 0
(zero).
33.19 Receiver Routing
This option displays if Zone Type is set for Auxiliary 1 or Auxiliary 2.
Press any top row key to select the Receiver Routing for the selected zone.
• Select NORM to send Alarm and Supv/Trbl messages from this zone to receiver 1
or receiver 2 as programmed within the receiver.
• Select 1 to send Alarm and Supv/Trbl messages from this zone to receiver 1 only,
regardless of the programming for that receiver.
• Select 2 to send Alarm and Supv/Trbl messages from this zone to receiver 2 only,
regardless of the programming for that receiver.
• Select BOTH to send Alarm and Supv/Trbl messages from this zone to both
receivers, regardless of the programming for either receiver.
33.20 Zone Number
Enter the zone number you want to program next. Return to section 32.1 and
follow the descriptions of each programming option. If all zones are programmed,
press the ARROW key at the ZONE NO: – display to continue.
Stop
34.1 Stop
PRIORITY NO YES
TRAFFICCOUNT
NO YES
ZONEAUDITDAYS:
0 - 0
RECEIVERROUTING
NORMAL
NORM12BOTH
ZONENO:-
00
STOP