User's Guide
Table Of Contents
- Panel Specifications
- Introduction
- System Components
- Installation
- Primary Power Supply
- Secondary Power Supply
- LED Operation
- RESET Button
- TAMPER Button
- PROG Programming Connection
- On-Board 1100 Series Wireless
- Wireless Zones
- Wireless Key Fobs and Outputs
- Flash LOAD Button
- On-Board Z-Wave Connection
- On-Board Wi-Fi Network
- Cellular Connection
- Wireless Keypads
- Programming Introduction
- Initialization
- Fast Programming
- Communication
- 22.1 Communication
- 22.2 Account Number
- 22.3 Transmission Delay
- 22.4 Communication Type
- 22.5 Backup Cellular
- 22.6 Test Time
- 22.7 Test Days
- 22.8 Check In Minutes
- 22.9 Fail Time
- 22.10 Send Communication Trouble
- 22.11 First Cell APN
- 22.12 Second Cell APN
- 22.13 Receiver 1 Programming
- 22.14 Alarm Reports
- 22.15 Supervisory/Trouble Reports
- 22.16 Opening/Closing and User Reports
- 22.17 Test Report
- 22.18 First IP Address
- 22.19 First IP Port
- 22.20 Second IP Address
- 22.21 Second IP Port
- 22.22 Receiver 2 Programming
- 22.23 Alarm Reports
- 22.24 Supervisory/Trouble Reports
- 22.25 Opening/Closing and User Reports
- 22.26 Test Report
- 22.27 First IP Address
- 22.28 First IP Port
- 22.29 Second IP Address
- 22.30 Second IP Port
- 22.1 Communication
- Network Options
- Messaging Setup
- Device Setup
- Remote Options
- System Reports
- System Options
- 28.1 System Options
- 28.2 System
- 28.3 Closing Code
- 28.4 Closing Check
- 28.5 Entry Delay 1
- 28.6 Exit Delay
- 28.7 Cross Zone Time
- 28.8 Power Fail Delay
- 28.9 Swinger Bypass Trips
- 28.10 Reset Swinger Bypass
- 28.11 Zone Activity Hours
- 28.12 Arm Activity Days
- 28.13 Time Zone Changes
- 28.14 Time Display
- 28.15 House Code
- 28.15.1 Detect Wireless Jamming
- 28.15.2 Wireless Audible Annunciation
- 28.16 Enable Keypad Panic Keys
- 28.17 Occupied Premises
- 28.18 Use False Alarm Question
- 28.19 Weather Zip Code
- 28.1 System Options
- Bell Options
- Output Options
- Output Setup
- Area Information
- Zone Information
- 33.1 Zone Information
- 33.2 Zone Number
- 33.3 Key Fob
- 33.4 Zone Name
- 33.5 Zone Type
- 33.6 Arming Zone Assignment
- 33.7 Area Assignment
- 33.7.1 Style
- 33.8 DMP Wireless
- 33.8.1 Serial Number Entry
- 33.8.2 Contact
- 33.8.3 Supervision Time
- 33.8.4 LED Operation
- 33.8.5 Disarm/Disable
- 33.8.6 Wireless PIR Pulse Count
- 33.8.7 Wireless PIR Sensitivity
- 33.8.8 Next Zone
- 33.9 1144 Series Key Fobs
- 33.9.1 Key Fob User Number
- 33.9.2 Key Fob Serial Number
- 33.9.3 Key Fob Supervision Time
- 33.9.4 Number of Key Fob Buttons
- 33.9.5 Key Fob Button Selection (Four Buttons)
- 33.9.6 Key Fob Button Selection (Two Buttons)
- 33.9.7 Button Action
- 33.9.8 Button Press Time
- 33.9.9 Arm/Disarm Area Selection
- 33.9.10 Output Number
- 33.9.11 Output Action
- 33.10 Alarm Action
- 33.11 Disarmed Open
- 33.11.1 Message To Transmit
- 33.11.2 Output Number
- 33.11.3 Output Action
- 33.12 Swinger Bypass
- 33.13 Prewarn Address
- 33.14 Entry Delay
- 33.15 Cross Zone
- 33.16 Priority
- 33.17 Traffic Count
- 33.18 Zone Audit Days
- 33.19 Receiver Routing
- 33.20 Zone Number
- 33.1 Zone Information
- Stop
- Set Lockout Code
- Appendix
- Listed Compliance Specifications
- Household Burglar-Alarm System Units ANSI/UL 1023
- Central Station Burglar Alarm Units ANSI/UL 1610
- Household Fire Warning System ANSI/UL 985 NFPA 72 Specifications
- False Alarm Reduction Programmable Options ANSI/SIA CP-01-2010
- Revisions to This Document
- Certifications
- Ordering Information
- Accessories
Digital Monitoring Products XTLplus Installation and Programming Guide
40
APPENDIX
Appendix
This section provides additional zone and system information.
36.1 Status List
The Status List is the current status of the system or records of recent system events that display on
alphanumeric keypads. For example, in Home/Away systems you may see the display SYSTEM READY.
If an event were to occur on the system, such as an AC failure, the keypad would also display the AC POWER
-TRBL message. This is a system event that is placed into the Status List to alert the user to a problem with
the system.
Some Status List items remain in the display until manually cleared and some are cleared automatically
when the condition returns to normal. Below is a list of status and event displays the keypad can show in the
Status List:
Description Must be manually cleared?
Fire and Supervisory zone alarms Yes - by Sensor Reset
Fire and Supervisory zone troubles No - clears when zone restores
Burglary zone alarms No - clears at disarming.
All other zone alarms No - clears when zone restores
Zone monitor displays No - clears after approximately 8 minutes
Day zone alerts No - clears after approximately 8 minutes
System monitor troubles No - clears when condition restores
(AC and battery trouble)
Armed status display No
(System On)
Disarmed status displays No
(System Ready, System Not Ready)
Remote keypad messages No
(Sent to the keypad by your ofce or central station)
The highest priority message is displayed on the keypad. When there are multiple items in the list, you can
use the COMMAND or Back Arrow keys to scroll forward or back through the items.
36.2 Transmission Delay
You can set Abort Reports to YES if Opening and Closing reports are not being sent.
If the area where the alarm occurred is disarmed during the Transmit Delay time, only an Abort Report (S45)
message is sent to the receiver. If the area where the alarm occurred is disarmed after the alarm message
is sent to the receiver but before the Bell Cutoff time expires, even if the alarm was silenced, an Alarm
Cancelled (S49) message is sent. The Alarm Cancelled report cannot be disabled.
36.3 False Alarm Reduction
System Recently Armed report
The System Recently Armed report (S78) is sent when a burglary zone goes into alarm within two minutes of
the system being armed.
36.4 Diagnostics Function
The XTLplus panel contains a Diagnostics function that allows you to test the integrity of the network
communication,
integrity of the cellular communication and cellular signal communication of the 265C to
the nearest tower for the cellular carrier.
The Diagnostics function also displays the panel settings. To use
Diagnostics, reset the panel, enter the Diagnostics code 2313 (DIAG), and press COMMAND.
MAC Address
Short for Media Access Control address. This hardware address uniquely identies each network node. Not
to be confused with an IP address, which is assignable. In the Diagnostics function, the MAC address is the
panel on-board network hardware address. Press any select key to display the panel MAC address. Press the
COMMAND key to view the next option.
Serial Number
This number is the network communicator serial number. Reference this number for communicator date-of-
manufacture, hardware version, etc. Press any select key to display the Serial Number. Press the COMMAND
key to view the next option.