User's Guide
Table Of Contents
- Panel Specifications
- Introduction
- System Components
- Installation
- Primary Power Supply
- Secondary Power Supply
- LED Operation
- RESET Button
- TAMPER Button
- PROG Programming Connection
- On-Board 1100 Series Wireless
- Wireless Zones
- Wireless Key Fobs and Outputs
- Flash LOAD Button
- On-Board Z-Wave Connection
- On-Board Wi-Fi Network
- Cellular Connection
- Wireless Keypads
- Programming Introduction
- Initialization
- Fast Programming
- Communication
- 22.1 Communication
- 22.2 Account Number
- 22.3 Transmission Delay
- 22.4 Communication Type
- 22.5 Backup Cellular
- 22.6 Test Time
- 22.7 Test Days
- 22.8 Check In Minutes
- 22.9 Fail Time
- 22.10 Send Communication Trouble
- 22.11 First Cell APN
- 22.12 Second Cell APN
- 22.13 Receiver 1 Programming
- 22.14 Alarm Reports
- 22.15 Supervisory/Trouble Reports
- 22.16 Opening/Closing and User Reports
- 22.17 Test Report
- 22.18 First IP Address
- 22.19 First IP Port
- 22.20 Second IP Address
- 22.21 Second IP Port
- 22.22 Receiver 2 Programming
- 22.23 Alarm Reports
- 22.24 Supervisory/Trouble Reports
- 22.25 Opening/Closing and User Reports
- 22.26 Test Report
- 22.27 First IP Address
- 22.28 First IP Port
- 22.29 Second IP Address
- 22.30 Second IP Port
- 22.1 Communication
- Network Options
- Messaging Setup
- Device Setup
- Remote Options
- System Reports
- System Options
- 28.1 System Options
- 28.2 System
- 28.3 Closing Code
- 28.4 Closing Check
- 28.5 Entry Delay 1
- 28.6 Exit Delay
- 28.7 Cross Zone Time
- 28.8 Power Fail Delay
- 28.9 Swinger Bypass Trips
- 28.10 Reset Swinger Bypass
- 28.11 Zone Activity Hours
- 28.12 Arm Activity Days
- 28.13 Time Zone Changes
- 28.14 Time Display
- 28.15 House Code
- 28.15.1 Detect Wireless Jamming
- 28.15.2 Wireless Audible Annunciation
- 28.16 Enable Keypad Panic Keys
- 28.17 Occupied Premises
- 28.18 Use False Alarm Question
- 28.19 Weather Zip Code
- 28.1 System Options
- Bell Options
- Output Options
- Output Setup
- Area Information
- Zone Information
- 33.1 Zone Information
- 33.2 Zone Number
- 33.3 Key Fob
- 33.4 Zone Name
- 33.5 Zone Type
- 33.6 Arming Zone Assignment
- 33.7 Area Assignment
- 33.7.1 Style
- 33.8 DMP Wireless
- 33.8.1 Serial Number Entry
- 33.8.2 Contact
- 33.8.3 Supervision Time
- 33.8.4 LED Operation
- 33.8.5 Disarm/Disable
- 33.8.6 Wireless PIR Pulse Count
- 33.8.7 Wireless PIR Sensitivity
- 33.8.8 Next Zone
- 33.9 1144 Series Key Fobs
- 33.9.1 Key Fob User Number
- 33.9.2 Key Fob Serial Number
- 33.9.3 Key Fob Supervision Time
- 33.9.4 Number of Key Fob Buttons
- 33.9.5 Key Fob Button Selection (Four Buttons)
- 33.9.6 Key Fob Button Selection (Two Buttons)
- 33.9.7 Button Action
- 33.9.8 Button Press Time
- 33.9.9 Arm/Disarm Area Selection
- 33.9.10 Output Number
- 33.9.11 Output Action
- 33.10 Alarm Action
- 33.11 Disarmed Open
- 33.11.1 Message To Transmit
- 33.11.2 Output Number
- 33.11.3 Output Action
- 33.12 Swinger Bypass
- 33.13 Prewarn Address
- 33.14 Entry Delay
- 33.15 Cross Zone
- 33.16 Priority
- 33.17 Traffic Count
- 33.18 Zone Audit Days
- 33.19 Receiver Routing
- 33.20 Zone Number
- 33.1 Zone Information
- Stop
- Set Lockout Code
- Appendix
- Listed Compliance Specifications
- Household Burglar-Alarm System Units ANSI/UL 1023
- Central Station Burglar Alarm Units ANSI/UL 1610
- Household Fire Warning System ANSI/UL 985 NFPA 72 Specifications
- False Alarm Reduction Programmable Options ANSI/SIA CP-01-2010
- Revisions to This Document
- Certifications
- Ordering Information
- Accessories
Digital Monitoring Products XTLplus Installation and Programming Guide
44
APPENDIX
36.8 Zone Type Descriptions
This section describes applications for the default zone types in Zone Information programming.
NT (Night Zone) - Controlled instant zone used for perimeter doors and windows and interior devices such as
PIRs and glassbreak detectors.
DY (Day zone) - Used for emergency doors or re doors to sound the keypad buzzer and display the zone
name when the zone is faulted. Day zones also will send alarm reports to the receiver during the system’s
armed periods.
EX (Exit zone) - Initiates the entry delay timer when its assigned area is fully armed. Also, can initiate an
exit delay timer to allow a user to exit an area after the arming process has started.
PN (Panic zone) - Used for connecting to mechanical devices that allow a user to signal an emergency alarm.
Panic zones can provide either a silent or audible alarm with or without reporting to a central
station receiver.
EM (Emergency zone) - These are used for reporting medical or other non-panic emergencies to the
central station.
SV (Supervisory zone) - Used to provide 24-hour zone supervision. Typical applications are high water, and
low and high temperature gauges.
FI (Fire zone) - Used for any type of powered or mechanical re detection device. Typical applications are
for smoke detectors, sprinkler ow switches, manual pull stations, and beam detectors.
FV (Fire Verify zone) - Used primarily for smoke detector circuits to verify the existence of an actual re
condition. When a Fire Verify zone initiates an alarm, the panel performs a Fire Reset. If any Fire zone
initiates an alarm within 120 seconds after the reset, an alarm is indicated. If an alarm is initiated after 120
seconds, the cycle is repeated.
A1 and A2 (Auxiliary 1 and Auxiliary 2) - These zones are similar to a Night zone and are typically used to
protect restricted areas within a protected premises. Auxiliary 2 zones do not appear in the Status List.
AR (Arming zone) - Allows you to connect a keyswitch to a zone and use it to arm and disarm the system.