User's Guide
Table Of Contents
- Panel Specifications
- Introduction
- System Components
- Installation
- Primary Power Supply
- Secondary Power Supply
- LED Operation
- RESET Button
- TAMPER Button
- PROG Programming Connection
- On-Board 1100 Series Wireless
- Wireless Zones
- Wireless Key Fobs and Outputs
- Flash LOAD Button
- On-Board Z-Wave Connection
- On-Board Wi-Fi Network
- Cellular Connection
- Wireless Keypads
- Programming Introduction
- Initialization
- Fast Programming
- Communication
- 22.1 Communication
- 22.2 Account Number
- 22.3 Transmission Delay
- 22.4 Communication Type
- 22.5 Backup Cellular
- 22.6 Test Time
- 22.7 Test Days
- 22.8 Check In Minutes
- 22.9 Fail Time
- 22.10 Send Communication Trouble
- 22.11 First Cell APN
- 22.12 Second Cell APN
- 22.13 Receiver 1 Programming
- 22.14 Alarm Reports
- 22.15 Supervisory/Trouble Reports
- 22.16 Opening/Closing and User Reports
- 22.17 Test Report
- 22.18 First IP Address
- 22.19 First IP Port
- 22.20 Second IP Address
- 22.21 Second IP Port
- 22.22 Receiver 2 Programming
- 22.23 Alarm Reports
- 22.24 Supervisory/Trouble Reports
- 22.25 Opening/Closing and User Reports
- 22.26 Test Report
- 22.27 First IP Address
- 22.28 First IP Port
- 22.29 Second IP Address
- 22.30 Second IP Port
- 22.1 Communication
- Network Options
- Messaging Setup
- Device Setup
- Remote Options
- System Reports
- System Options
- 28.1 System Options
- 28.2 System
- 28.3 Closing Code
- 28.4 Closing Check
- 28.5 Entry Delay 1
- 28.6 Exit Delay
- 28.7 Cross Zone Time
- 28.8 Power Fail Delay
- 28.9 Swinger Bypass Trips
- 28.10 Reset Swinger Bypass
- 28.11 Zone Activity Hours
- 28.12 Arm Activity Days
- 28.13 Time Zone Changes
- 28.14 Time Display
- 28.15 House Code
- 28.15.1 Detect Wireless Jamming
- 28.15.2 Wireless Audible Annunciation
- 28.16 Enable Keypad Panic Keys
- 28.17 Occupied Premises
- 28.18 Use False Alarm Question
- 28.19 Weather Zip Code
- 28.1 System Options
- Bell Options
- Output Options
- Output Setup
- Area Information
- Zone Information
- 33.1 Zone Information
- 33.2 Zone Number
- 33.3 Key Fob
- 33.4 Zone Name
- 33.5 Zone Type
- 33.6 Arming Zone Assignment
- 33.7 Area Assignment
- 33.7.1 Style
- 33.8 DMP Wireless
- 33.8.1 Serial Number Entry
- 33.8.2 Contact
- 33.8.3 Supervision Time
- 33.8.4 LED Operation
- 33.8.5 Disarm/Disable
- 33.8.6 Wireless PIR Pulse Count
- 33.8.7 Wireless PIR Sensitivity
- 33.8.8 Next Zone
- 33.9 1144 Series Key Fobs
- 33.9.1 Key Fob User Number
- 33.9.2 Key Fob Serial Number
- 33.9.3 Key Fob Supervision Time
- 33.9.4 Number of Key Fob Buttons
- 33.9.5 Key Fob Button Selection (Four Buttons)
- 33.9.6 Key Fob Button Selection (Two Buttons)
- 33.9.7 Button Action
- 33.9.8 Button Press Time
- 33.9.9 Arm/Disarm Area Selection
- 33.9.10 Output Number
- 33.9.11 Output Action
- 33.10 Alarm Action
- 33.11 Disarmed Open
- 33.11.1 Message To Transmit
- 33.11.2 Output Number
- 33.11.3 Output Action
- 33.12 Swinger Bypass
- 33.13 Prewarn Address
- 33.14 Entry Delay
- 33.15 Cross Zone
- 33.16 Priority
- 33.17 Traffic Count
- 33.18 Zone Audit Days
- 33.19 Receiver Routing
- 33.20 Zone Number
- 33.1 Zone Information
- Stop
- Set Lockout Code
- Appendix
- Listed Compliance Specifications
- Household Burglar-Alarm System Units ANSI/UL 1023
- Central Station Burglar Alarm Units ANSI/UL 1610
- Household Fire Warning System ANSI/UL 985 NFPA 72 Specifications
- False Alarm Reduction Programmable Options ANSI/SIA CP-01-2010
- Revisions to This Document
- Certifications
- Ordering Information
- Accessories
Digital Monitoring Products XTLplus Installation and Programming Guide
46
APPENDIX
36.10 Common Keypad Messages
Message Meaning Possible Solutions
INVALID CODE
The user code you have entered is not
recognized by the system.
Check the user code and try again.
CLOSING TIME The schedule has expired but the
system has not been armed.
Users still on the premise should arm the system
or extend the schedule to a later time.
KEYPAD NAME - NOPWR
Wireless keypad is not getting proper
power.
Check that AC/DC transformer is plugged in
correctly.
AC TROUBLE The system AC is low or missing. Check that the AC connections are good.
BATTERY TROUBLE
The System battery is either low or
missing.
Check that the battery connections are good
and the battery is still good.
SYSTEM TROUBLE or
SERVICE REQUIRED
There is a problem with one or more
components in the system.
Press the RESET button for 1-2 seconds.
SYSTEM BUSY
The system is performing another task
with a higher priority.
Wait a few moments for the system to complete
the task. If the message displays for a long
period of time, the processor could be locked
up.
TRANSMIT FAIL
The panel has attempted to
communicate with the central station
10 times and has not succeeded.
Verify your communication type, account
number, and IP address.
ENTER CODE (When
entering Programming)
A lockout code has been programmed
for the panel.
Enter the lockout code.
Listed Compliance Specications
37.1 Introduction
The programming and installation specications contained in this section must be completed when installing
the XTLplus in accordance with any of the ANSI/UL or SIA burglary standards. Additional specications may
be required by a particular standard.
37.2 Use Marking
Commercial Central Station, Household Burglar Control Unit.
37.2 Locations and Wiring
Locations and wiring methods shall be in accordance with the National Electrical Code, ANSI/NFPA 70 and the
Standard for Installation and Classication of Burglar and Holdup Alarm Systems, UL 681.
37.3 NFPA 72
This equipment should be installed in accordance with Chapter 29 of the National Fire Alarm Code,
ANSI/NFPA 72, (National Fire Protection Association, Batterymarch Park, Quincy, MA 02269). Printed
information describing proper installation, operation, testing, maintenance, evacuation planning, and repair
service is to be provided with this equipment. Warning: Owner’s instruction notice, not to be removed by
anyone except occupant.
37.4 Types Of Service
Suitable for Central Station Burglar. Suitable for Household Fire and Household Burglar. Test weekly. The
XTLplus has not been evaluated by Intertek for Household Fire.
37.5 Police Station Phone Numbers
The XTLplus must not be programmed to communicate with a police station.
37.6 Bypass Reports
The bypass reports must be programmed as YES for all listed burglary applications.
37.7 System Testing
The system must be tested once per week and Checked by a qualied technician once every three (3) years.
COMPLIANCE