Installation Guide

2 1106 INSTALLATION GUIDE | DIGITAL MONITORING PRODUCTS
MOUNT THE 1106
For ETL listed and commercial installations, use the supplied
screws when mounting the transmitter and the magnet.
Mount the Transmitter
1. If mounting with screws, remove the battery. If mounting
with double-sided tape, place the tape on the back of the
transmitter.
2. Hold the transmitter in place with the magnetic reed
switch closest to where the magnet will be mounted. See
Figure 2. Ensure the transmitter and the magnet will be no
more than 1/2” (1.3cm) apart.
3. If using screws, place the supplied #4 screws into the two
mounting holes and secure the transmitter to the surface.
If using double-sided tape, place the transmitter on the
surface.
4. Snap the transmitter cover back onto the base.
Mount the Magnet
Standard Installation
1. Push the supplied magnet into the magnet cover.
2. Hold the magnet base on the door closest to the
magnetic reed switch, no more than 1.3cm (0.5in) from the
transmitter.
3. If using screws, use the provided #4 screws to mount the
base. See Figure 3. If using double-sided tape, place the
tape on the back of the base and place on the surface.
4. Snap the cover onto the base.
Commercial Installation
1. Push the supplied magnet into the magnet cover.
2. Place and hold the magnet cover directly on the door
closest to the magnetic reed switch, no more than 1.3cm
(1.5in) apart from the transmitter.
3. Use the provided #4 screws to mount the cover.
See Figure 4.
4
5
TEST THE 1106
After installing the 1106, perform a Wireless Check-in Test to confirm the 1106 is communicating with the
panel.
At the keypad, enter 8144 (WALK) and select WLS. If the 1106 fails to check in at the keypad, relocate the
wireless device, receiver, or panel.
Figure 3: Standard Installation
Figure 4: Commercial Installation
Wall Mount
Screw Holes
Magnetic Reed
Switch
Figure 2: Transmitter Components
3
The 1106 provides a Survey LED capability to allow one person to confirm communication with the
wireless receiver or panel while the cover is removed.
1. Hold the 1106 in the exact desired location.
2. Press the tamper switch to send data to the panel and determine if communication is confirmed or
faulty.
Confirmed: If communication is confirmed, for each press or release of the tamper switch
the LED blinks immediately on and immediately o. Repeat this test to confirm five separate
consecutive LED blinks. Any indication otherwise means proper communication has not been
established.
Faulty: If communication is faulty, the LED remains on for about 8 seconds or flashes multiple
times in quick succession. Relocate the 1106 or wireless receiver until the LED confirms clear
communication.
SELECT A LOCATION