Installation Guide
1106 INSTALLATION GUIDE | DIGITAL MONITORING PRODUCTS 3
Connect External Contacts
Refer to Contacts and Zone Information in the appropriate panel programming guide for more information. DMP
recommends using 18 or 22 AWG un-shielded wire. If you use both the magnet reed switch in the 1106 transmitter
and an external contact, use consecutive zone numbers when connecting them to the panel.
1. Remove the cover of the 1106.
2. Use a flat head screwdriver to loosen the two screws on the 1106 terminal block. See Figure 5.
3. Insert the external contact wiring into the 1106 terminal block and tighten the screws.
4. Depending on how the contact was programmed in the Program the Panel section, connect the other ends of
the wires to the external contact as either normally open (N/O) or normally closed (N/C) without an end-of-
line resistor.
Figure 5: Connect External Contact
MODEL 1106
CR123
External Contact
Terminal Block
1106
Door
Window
External
Contact
ADDITIONAL INFORMATION
1. Open the transmitter housing to expose the inside of the 1106. See Figure 1.
2. Remove the old battery, observe polarity, and place the new battery in the holder.
3. Snap the cover back on the 1106.
Replace the Battery
Once the battery is replaced, a sensor reset is required at the keypad to clear the LOBAT message.
1. On an LCD Keypad, press and hold 2 for two seconds. On a Graphic Touchscreen Keypad,
press RESET.
2. Enter your user code, if required. The keypad displays SENSORS OFF followed by SENSORS
ON.
Sensor Reset to Clear LOBAT
Magnet
Program one
zone as an
internal contact.
Program the next
consecutive zone as
an external contact.
EXTERNAL CONTACTS