Programming instructions

XR150/XR350/XR550 Series Programming Guide Digital Monitoring Products
17
DEVICE SETUP
Note: When OVERRIDE is YES and there are no areas programmed in ACCESS AREAS, the
door schedule for that device does not work. Either set OVERRIDE to NO or enter an area
number in ACCESS AREAS.
6.16 Auto Force Arm Device?
Select YES to have all Display Areas assigned to this keypad automatically arm and force
arm faulted zones at arming. The user is not prompted to select areas to arm or force arm
faulted zones after choosing ARM at the keypad. If Closing Code is programmed as YES,
only the matching areas between the Display Areas and the User Code’s authorized areas
arm. Also, when YES is selected, the user is not prompted to select areas to disarm after
entering a code at Entry Delay or after choosing Disarm at the keypad. All matching areas
assigned to the User Code and to this keypad are automatically disarmed. When NO is
selected, the user is prompted to select areas (ALL NO YES) and choose to force arm or
bypass at arming and disarming. Default is NO.
6.17 Door Real-Time Status?
Select YES to have real-time door status messages sent to PC Log reporting and Entré
reporting for this device. Messages are sent anytime the panel turns the door relay on or
off. Default is NO.
6.18 Send Door Forced Message?
Select YES to have the panel send a real-time door status message of Forced Open (FO)
to PC Log reporting and Entré reporting when the door relay is off, but the door zone has
transitioned from its normal state. Default is NO.
6.19 Program 734/734N Options
Select YES to program a 734 or a 734N/734N-WiFi Wiegand Interface Module. The options
displayed for a 734 or 734N are the same.
To program the 734, the Device Type must be set to DOOR and the Device Communication
Type must be set to KPD-BUS.
To program the 734N/734N-WiFi, the Device Type must be set to DOOR and the Device
Communication Type must be set to NETWORK.
6.19.1 Activate Zone 2 Bypass
Select YES to activate the Bypass option.
Selecting NO allows standard zone operation on Zone 2 and displays the ACTIVATE ZONE 3
REX option. Default setting is NO.
If the door being released by the 734/734N/734N-WiFi module is protected (contact
installed), you can provide a programmable Bypass entry/exit timer by connecting its contact
wiring to the 734/734N/734N-WiFi module Zone 2. When the on-board Form C relay activates
and the user opens the door connected to Zone 2, the zone is bypassed for the number of
seconds programmed in ZONE 2 BYPASS TIME allowing the user to enter/exit.
If Zone 2 does not restore (door closed) within the programmed bypass time, the
734/734N/734N-WiFi piezo pulses during the last ten seconds. If Zone 2 restores prior to
the end of the programmed time, the piezo silences. If the zone does not restore before
the programmed time, the 734/734N/734N-WiFi ends the bypass and indicates the open or
short zone condition to the panel.
6.19.2 Zone 2 Bypass Time
Enter the number of Bypass seconds to elapse before the Bypass timer expires. Range is
from 20 to 250 seconds. Press any top row select key to enter the number of seconds. If the
door remains open when the timer expires a zone open/short is sent to the panel for Zone
2. The default is 40 seconds.
6.19.3 Relock on Zone 2 Change?
Selecting NO leaves the relay on for the door access time when Zone 2 restores.
Selecting YES turns the 734/734N/734N-WiFi relay off and relocks the door when Zone 2
changes state. The default is NO.
6.19.4 Activate Zone 3 Request to Exit
Selecting YES activates the Zone 3 Request to Exit (REX) option.
Selecting NO allows standard zone operation on Zone 3 and displays the ACTIVATE ONBOARD
SPEAKER option. Default setting is NO.
Optionally connect a PIR (or other motion sensing device) or a mechanical switch to Zone
3 to provide REX capability to the system. When Zone 3 shorts, the on-board Form C relay
activates for the programmed number of seconds. During this time, the user can open the
protected door to start the programmed Bypass entry/exit timer. After the programmed
number of seconds, the relay restores the door to its locked state.
AUTO FORCE ARM
DEVICE? NO YES
DOOR REAL-TIME
STATUS? NO YES
SEND DOOR FORCED
MESSAGE? NO YES
PROGRAM 734
OPTIONS? NO YES
ACTIVATE ZONE 2
BYPASS? NO YES
ZONE 2 BYPASS
TIME: 40
RELOCK ON ZONE 2
CHANGE? NO YES
ACTIVATE ZONE 3
REX? NO YES