Programming instructions

Digital Monitoring Products XR150/XR350/XR550 Series Programming Guide
54
FEATURE UPGRADE
Feature Upgrade
21.1 Feature Upgrade
In the Programming Menu, pressing COMMAND at the SET LOCKOUT CODE option displays
FEATURE UPGRADE. This allows you to enable additional features in the panel. Press any
top row Select key to display the rst available feature. ENABLED or DISABLED displays
indicating whether this feature is currently used in this panel. Press the COMMAND key to
display additional feature(s).
To enable a feature, press any top row Select key anywhere in the features list to display
the ENTER KEY option.
Enter the factory-supplied feature key for the specic panel and press the COMMAND key.
The feature specic to the key displays as ENABLED.
If the feature key entered is not accepted, the ENTER KEY option displays again.
Re-enter the feature key and press the COMMAND key.
21.1.1 Encryption
Enable this feature to provide 128-bit or 256-bit AES data encryption. This feature upgrade
can only be enabled on an XR550 panel with network. For installations where an XR550
panel is installed, it is recommended the XR550 be replaced with an XR550 panel with
encryption. To verify encryption installation, access System Status in the User Menu to
verify the encryption status (OFF, ON). If the status displays OFF, a Passphrase has not been
entered in Network Options and data transmissions are not encrypted. See Network Options
to set up a Passphrase.
21.1.2 All No Yes Option
This feature offers the ability to disable the ALL NO YES option at arming or disarming.
When this feature is enabled, the ALL NO YES option does not display at any system
keypad during arming or disarming. Each area assigned to the user prole is chosen to be
armed or disarmed independently.
21.1.3 Service User Authentication
This feature offers the ability to authenticate service personnel before allowing access
to panel programming or performing any user operations. When this feature is enabled
and a valid Service User code is entered for system operation or 6653 is entered for
programming, the Service Code entry option displays.
When the service person enters the Service Code, the panel authenticates the code with
the Service Code preprogrammed in the SCS-1R receiver, and access to panel programming
or the User Menu is granted. The Service Code can be used for system operation for 30
minutes before authenticating again. If the code entered is not validated, access to
programming or the User Menu using the Service User code is denied.
Note: The Service User code is user number zero (0) and can only be created in the panel
remotely. The SCS-1R receiver must have rmware version 902 or higher to authenticate
service personnel.
Purchasing Feature Upgrades
To purchase a feature upgrade, you may contact DMP Customer Service with the feature
you would like to enable and the panel serial number. The serial number(s) should be sent
in writing via e-mail or fax. A separate feature key is issued for each panel. The feature key
only enables the requested feature on the specied panel.
The panel serial number can be located several different ways:
Printed on a label located on the right side of the PCB.
Using panel diagnostics. See the Appendix.
Using Remote Link™ (version 1.18 or greater). See the Remote Link Users Guide
(LT-0565).
— Initial Panel Connection screen
— System Information screen.
FEATURE UPGRADE
ENTER KEY
-
ENCRYPTION
DISABLED
ALL NO YES OPTN
DISABLED
SVC USER AUTH
DISABLED