UL 365 and 609 SPECIFICATIONS
Police Station Connected and Local Burglar Alarm Units
and Systems
19.1 Entry delay
The maximum entry delay used must not be more than 60 seconds when using the Model 349A Grade A housing. See the
XR6/XR10 Programming Guide (LT-0230).
19.2 Grade A bell
A Grade A local audible signal appliance must be used.
19.3 Bell cutoff
The bell cutoff time cannot be less than 15 minutes. See the XR6/XR10 Programming Guide (LT-0230).
19.4 Automatic bell test
The Automatic Bell Test option must be programmed as YES. See the XR6/XR10 Programming Guide (LT-0230).
19.5 Grade A Mercantile
For Grade A Mercantile and Police Station Connect operation the Model XR6/XR10 must be mounted in a Grade A attack
resistant housing, (DMP Model 350A).
19.6 Mercantile Safe and Vault
When the DMP Model 350A housing is used, the panel provides operation as a mercantile safe and vault alarm. Bell
Supervision and wiring must be in accordance with UL 681. If the panel is mounted outside the safe or vault, tamper
protection and the Sentrol Model 5402 or Potter EVD listed vibration detectors should be used. The XR6/XR10 does not
provide operation as a Bank Safe and vault alarm.
19.7 Line security for Police Connect
Basic line security is provided when the Model XR6/XR10 is configured as a dialer system.