User`s guide

14 XRSuper6 User Menu
Bypass Zones
User Code Level: Master or Standard.
Function: Allows you to bypass a zone prior to arming the system.
Bypassing is usually done when a zone cannot be restored to
normal and you want to arm the system. Once bypassed, the
system will not respond to any activity on the zone.
A zone can be bypassed only while it is disarmed. Since Fire,
Panic, Emergency, and Supervisory zones are always armed, they
can never be bypassed.
The Bypass Zones function can also be used to restore a bypassed
zone back into the system. This can only be done while the zone
is disarmed.
When Bypass Zones is selected, a report of the bypassing can be
sent to your central station. This is optional and can be
programmed for you at any time.
Using the Bypass Zones Function
1. Access the User Menu.
2. Press the COMMAND key until BYPASS ZONES? displays.
3. Press any one of the Select keys. The keypad displays ZONE:
- RST BYPS.
4. To reset a zone, enter the zone number and press the Select
key under RST.
5. To Bypass a zone, enter the zone number and press the Select
key under BYPS.
Zone Monitor
User Code Level: Master and Standard.
Function: Allows the system to monitor selected disarmed zones
(doors, windows, or motion detectors). When a monitored zone
is tripped, the keypad sounds a tone and displays the zone name.
This is an ideal feature for monitoring doors to tell when someone
comes in or goes out and for testing the system.
You can place any combination of disarmed zones in Zone Monitor
but only the most recently tripped zone is displayed. The displayed
zone name clears automatically after a short time or when the
zone is armed.
Using Zone Monitor as part of your weekly system test: After
using the System Test function, place all perimeter and interior
zones in Zone Monitor. Starting at the front door, open and then
close each door in the premises. You should hear the keypad
beep each time. The keypad will also display the name of each
zone as the device is opened.
Once all protected doors and windows have been tested, walk in
front of each motion detector, open and close each window,
and trip any other protection devices on the system. If at any
time during your weekly testing a device does not cause the
keypad to beep, call the service department for assistance.