Operating instructions
Description of menu G3 Series
Description of menu
5-32
000015,031,02-2009, jmu
5
The window range is determined by entering two reference points on the working
surface.
Procedure
⇨ Use the direction keys to position the active pointer in the lower right-hand corner
of the required window area and confirm
⇨ Use the direction keys to position the active pointer in the upper left-hand corner
of the required window area and confirm
2010
2-6-1-4 Show window
This func tion moves the head along the limits of t he clipping window.Move along th e window limi ts?Display of th e window limit s is running. ..
Display of the window area. The limits of the activated window are shutdown.
2002
2-6-1-5 Top left X
Defines the t op left X position of a soft clip ping window.
X coordinate of the upper left-hand corner of the window area.
2003
2-6-1-6 Top left Y
Defines the t op left Y position of a soft clip ping window.
Y coordinate of the upper left-hand corner of the window area.
2004
2-6-1-7 Bottom right X
Defines the bot tom right X po sition of a s oft clipping win dow.
X coordinate of the lower right-hand corner of the window area.
2005
2-6-1-8 Bottom right Y
Defines the bot tom right Y po sition of a s oft clipping win dow.
Y coordinate of the lower right-hand corner of the window area.
2011
2-6-2 Window 2 options
Definition of clipping win dow 2.
Define window 2
3 Functions
No help tex t is available for this menu.
Functions for setting material hold-down, router, dust extractor, compressor
1981
3-1-1 Vacuum
Menu for s etting and changi ng the vacuum.
Setting the material hold-down by vacuum.
1989
3-1-1-1 Vacuum status
No help tex t is available for this parameter.Of fSuctionBlowingIm pact
Vacuum status: On / Off
3-1-1-5 Power level
No help tex t is available for this parameter.UndefinedLevel 1Le vel 2Level 3Level 4Leve l 5Level 6Le vel 7Level 8Level 9Level 10
Select power level between 1 and 10. The power level is monitored by a vacuum sen-
sor and adapted to the requirements.
3-2-1-1 Rpm
No help tex t is available for this parameter.
Display of RPM
2632
3-2-1-2 Increase RPM
Automatic initialisation with AKI
Use the key to increase the RPM. Keep this key held down to increase the RPM
more quickly.
2633
3-2-1-3 Decrease RPM
Automatic initialisation with AKI
Use the key to decrease the RPM. Keep this key held down to reduce the RPM
more quickly.
2634
3-2-1-4 Switch on router
Automatic initialisation with AKI