Operating instructions

Description of menu G3 Series
Description of menu
5-38
000015,031,02-2009, jmu
5
AUTO is usually used to automatically determine the optimum white balance. If
an optimum result cannot be achieved with AUTO then you can identify the ap-
propriate light source.
Room lighting
Fl. lighting (fluorescent tubes)
•Sun
3623
3-5-6 BLC
No help tex t is available for this parameter.Of fOn
The backlight correction (BLC) corrects colour distortions. In the case of reflective
materials e.g. the ceiling lighting is reflected. This may distort the image.
The backlight correction (BLC) can be switched on or off.
1594
4User settings
Menu for c hanging the use r-depende nt settin gs.
Access to menus and functions is blocked according to the user level. The user
levels have a hierarchical structure. This means that the next highest user also has
the access rights to the menu functions that the subordinate user has.
4-1 User
The access rights are dependent on the user authorisation. User: Productio n parameters are available. Operator: Setting parameters are availa ble. Service: P arameters for serv ice settings are availableUser 1User 2User 3Oper atorServiceFactoryR&D
Select user level and confirm with OK
⇨Press R
Enter user code and confirm with OK
1596
4-2 Password
Certain user authorisations can only be set using a password. This password can be set here.
Enter your user code
The user level is approved and is displayed under
User
4-1
3615
4-3 Start user
No help tex t is available for this parameter.User 1User 2User 3OperatorServiceFactoryR&D
Setting of which user level is automatically active once the cutter has been started
up.
1806
22
User Description
Users 1 - 3 All menus and functions that are needed for the
operation of the machine are accessible
Operator Certain settings work is permitted
Service Cutter settings that can only be carried out by
authorised service personnel
Factory setup Basic settings already implemented at Zünd