Operating instructions

Malfunctions G3 Series
Locate error
6-2
000012,03,02-2009, jmu
6
Error display on the status and error display (example)
The error is displayed as a sequence. No redundant figures of the error code will be
shown in this display.
Example: The error 0x0001D503 is abbreviated to the figures 1D503.
If several errors occurred one after the other then these are combined together in a
group. The error which occurred first is displayed at the start of the group. All other
errors follow in order.
Fig. 6-2 Error display on the status and error display
6.2.1 Error display
If a number of errors occurred then the first error of this sequences is always shown
on the display of the operating unit (group).
All errors which have occurred after the confirmation of the last error are gathered
together in a group.
Display last error group
Use SHIFT+ (2nd soft key) to display all errors of the last group.
Display list of open errors
While the first error is shown on the display, SHIFT+ (1st soft key)
can be used to display a list with all open errors.
Item Sequence Description
1 Introduction The error group is started with the introduction
sequence
2 Error code 1 Display of the error code recorded first
3 Separator The display of the error is completed and
another error follows
4 Error code 2 Display of the next error code
5 Separator The display of the error is completed and
another error follows
6 Error code 3 Display of the next error code
7 Conclusion The display of the group has been completed