Operating instructions
G3 Series Malfunctions
Error messages
6-7
000012,03,02-2009, jmu
6
Contact service
0x0000BB04 N status error before loading the Altera.
No help available
192
Contact service
0x0000BC04 Altera not ready.
No help available
193
Contact service
0x0000BD02 HAL: Err. reading 16 bit value.
HAL file row number: %0s
An error occurred when reading a16 bit value from the HAL file. The row is discarded.
194
Contact service
0x0000C002 The response to the command was not received in the expected time.
197
Contact service
0x0000C600 The cutter is not in a permitted operating status for this action.
The sequencer m ust be in wait ing status for the function whic h has been call ed up. Stop any action on the cutter and test it again.
203
Cause
The sequencer must be in waiting status for the function which has been called up.
Solution
Wait until vectors have been processed.
0x0000D204 AD converter error.
Index: %0s
One or more axes cannot be controlled. Check connections.
215
Contact service
0x0000D603 Error in the controller.
Index: %0s
The controller has detected an error.
219
Contact service
0x0000DC02 Internal error:
The allocation for a watch job could not be found.
No help available
226
Contact service
0x0000DD04 Wrong voltage on amplifier.
Index: %0s
Error index: 0x0001 -> PG_VMOT_X 0x0002 -> PG_VMOT_Y 0x0004 -> PG_VMOT_VAC 0x0008 -> -12VAn 0x0010 -> 24V_NA 0x0020 -> 24V 0x0040 -> 24VF_EX 0x0080 -> +12VF 0x0100 -> +12VAn 0x0200 -> VMOT
227
Contact service
0x0000DE03 Overload identified.
No help available
228
Check parameter speed/acceleration, adjust if necessary.
0x0000E204 Err. on axis voltages.
Axis code: %0s
An error occurr ed during a vol tage check. The hardware is pro bably defective. 0x01 PG_VMOT_X 0x02 PG_VMOT_Y 0x04 PG_VMOT_VAC
232
Contact service
0x0000ED03 Head within the clipping area.
Release the clipping area again or put the initialisation tool back in the park position.
243