Operating instructions
Malfunctions G3 Series
Error messages
6-8
000012,03,02-2009, jmu
6
Cause
It was detected that the head is currently in a hard clipping area.
This was probably because a hard clipping window was defined at the point where
the head is positioned or because a hard clipping area was activated.
Solution
The head must be brought out of this area or the hard clipping window must be
defined differently. The head can only be moved out of this area manually.
If an automatic initialisation tool is available, then position this back in the park station
so that the clipping window is free again.
0x0000EE02 HAL: Error during the reading of the comm devices in the bus definition.
HAL file row number: %0s
An error occurred when reading the comm devices in the bus defin ition. There is probably an e rror in the H AL file.
244
Contact service
0x0000EF02 HAL: Error during the reading of the device ID in the bus definition.
HAL file row number: %0s
An error occurred when reading the device ID in the bus definition. There is probably an error in the HAL file.
245
Contact service
0x0000F203 Safety module gave notification of error
Has an emergency stop key been pressed?
Mode %0s
The safety module has triggered an error. 0x01 -> No emergency stop active 0x02 -> 24 V_NA not available 0x04 -> Emergency stop still active 0x08 -> E mergency stop not active 0x10 -> Safe_Con i ncorrect 0x20 -> A 1_EMM inc orrect
251
Cause
Error in basic function::change emergency stop()
0x01 -> No emergency stop active
0x02 -> 24V_NA still available
0x04 -> Emergency stop still active
0x08 -> Emergency stop not active
0x10 -> Safe_Con incorrect
0x20 -> A1_EMM incorrect
Solution
Check emergency module or basic function board
0x0000F304 Incorrect voltages on the BASIC FUNCTION BOARD.
Possibly a hardware error on the basic function board.
252
Contact service
0x0000F403 HAL: Unknown internal IO port.
HAL file row number: %0s
The stated IO port of the IO b it could not be found.
253
Contact service
0x0000F502 HAL: No interrupt signal was assigned to an active port/bit.
No help av ailable
254
Contact service
0x0000FA01 Editor open on other op. unit
Shut the editors on all other operating units and try again.
259