Operating instructions

Malfunctions G3 Series
Error messages
6-10
000012,03,02-2009, jmu
6
Contact service
0x00011F02 The command may not be carried out in this operating status. Change the operating
status in order to carry out the command.
296
Cause
The instruction was discarded because it is not permitted in the current instruction
mode.
Solution
Switch the system to the operating status OFFLINE or ONLINE and carry out the
instruction again.
0x00012103 Light barrier triggered
LB = %0s Type = %1s
A light barrier ha s triggered, eith er because it is defective or be cause its beam o f light was interru pted. In the first p arameter, the erro r states which light barrier it is related to and in the second it st ates what kind o f error it is. lb: 0 = Front light barrier lb: 1 = Back light barrier lb: 2 = Left-hand reflex light barri er lb: 3 = Right-han d reflex light ba rrier type: 1 = Beam o f light interrupte d type: 2 = Light b arrier probably defectiv e
298
Cause
A light barrier has triggered, either because it is defective or because its beam of light
was interrupted.
In the first parameter, the error states which light barrier it is related to and in the
second it states what kind of error it is.
LB: 0 = Front light barrier
LB: 1 = Back light barrier
LB: 2 = Left-hand reflex light barrier
LB: 3 = Right-hand reflex light barrier
Type: 1 = Beam of light interrupted
Type: 2 = Light barrier probably defective
Important !
Be aware that it is not guaranteed that the connection of the front and back
light barriers have been swapped.
Solution
Remove object from the beam of light.
Check that the light barrier is correctly connected
Check for cable interrupt
Replace light barrier.
0x00012902 This function or this parameter is not available for this module. Change the module.
If this error o ccurs, you have a ttempted to car ry out a function or set a paramet er on the curr ent module. The error is that the current module does not r ecognise t his parameter or t hat the function is n ot available on this module.
307
Contact service
0x00012A03 This function is not permitted from this task.
Command: %0s
Caller index: %1s
This is a progr amming error. Plea se inform the ma nufacturer.
308
Contact service
0x00012B03 This initialisation mode is not supported.
This is a progr amming error. Plea se inform the ma nufacturer.
309
Contact service