Operating instructions
G3 Series Malfunctions
Error messages
6-11
000012,03,02-2009, jmu
6
0x00012C04 Axis inspection err.
Axis %0s
Error %1s
An error occurr ed during the in spection of the axes. The motor or encoder may be incorrectly connected. Ax is: Each half byte stand s for an axis whi ch may have an e rror. The correspon ding error code stands for this axis. 0=X, 1=Y etc. Erro r code: 0x1 zero reference mark Error 0x2 Overr ide 0x4 m ax current excee ded 0x8 min current not reached
310
Contact service
0x00012F02 HAL: Not possible to configure the IO.
HAL file row number: %0s
It is not possible to define the individual bits as inp uts or outputs o n the HAL element.
314
Contact service
0x00013002 HAL: An output port has been defined for this HAL element.
An attempt was made to set a v alue on an HAL element althoug h this HAL elem ent cannot be use d as an outpu t. This HAL elem ent is only an input.
315
Contact service
0x00013102 HAL: Not possible to set the IO direction.
HAL file row number: %0s
No help available
316
Contact service
0x00013202 HAL: An input port has been defined for this HAL element.
An attemp t was made to rea d a value on an HAL elemen t althoug h this HAL element cannot be used as an input. This HAL element is only an output.
317
Contact service
0x00013303 Module selection error.
An error occurred during t he module selecti on.
320
Contact service
0x00013704 No reference to the module carriage.
Internal erro r. The program h as no reference t o a tool head. Check the connections.
324
Contact service
0x00013803 Insufficient parameters
Insufficient pa rameters for the command (0x %0s)
325
Contact service
0x00013B01 Module not available.
Select an other module.
328
Cause
The currently installed tool head cannot be accessed on the required module.
Solution
Select the correct module or change the tool
0x00014103 Z axis init error.
Axis: %0s
Status: %1s
No help available
334
Contact service
0x00014203 T axis init error.
Status: %1s
No help available
335
Contact service
0x00014403 Incorrect module active.
Select the module %0s
The incorrec t module is ac tive for a ren ewal. Change to the correct module.
337