Operating instructions
G3 Series Malfunctions
Error messages
6-13
000012,03,02-2009, jmu
6
Cause
The system status may not be changed because the system is in the operating status
STOPPED. It is only possible to leave the operating status STOPPED using
operating unit 1.
Solution
Change operating status via operating unit 1.
0x00015502 Incorrect parameter for the arc command.
Check the para meters of the arc command.
354
Cause
An attempt was made to draw a circle. The transferred parameters do not correspond
with the definition. This error is transmitted if the data length of the message is
incorrect.
Solution
Correct the parameters.
0x00015604 Module/tool voltage error.
Index: %0s
Error index: 0x0000 -> PG_24V 0x0400 -> PG_24V 0x0800 -> PG_53V
355
Contact service
0x00015702 HP-GL response function not found.
Check the software version and inform your service centre.
356
Contact service
0x00015802 Incorrect parameter.
Incorrect param eter for the H P-GL TR command .
357
Cause
Incorrect parameters were transferred when switching the tangential rotation on or
off.
Solution
Correct the parameters.
0x00015901 The entire database was successfully reset to the default values.
All database parameters of t he currently loaded formula were reset to their default values.
358
Contact service
0x00015A01 Parameter successfully set to the default value.
All parameters of a part form ula were succ essfully reset t o their default values. However, they have not been resaved.
359
Contact service
0x00015B01 Formula parameter successfully saved.
All database parameters of a s elected part form ula have been su ccessfully saved.
360
Contact service
0x00015C02 Unknown parameters for the output special command (OP).
This comm and is not availa ble in this firmw are, or in correct parameters were transferred.
361
Contact service
0x00015D02 An error occurred when setting the pen pulse duration.
Set short er pulse duration.
362
Contact service