Operating instructions

G3 Series Malfunctions
Error messages
6-25
000012,03,02-2009, jmu
6
Cause
An excessive temperature was measured on the X motor.
Solution
Wait until the temperature has cooled down.
Check the sensor.
0x0001EE03 Excess temperature X axis motor.
No help available
518
Cause
X motor displays an excess temperature.
Solution
Wait until the temperature reduces.
0x0001EF03 No sealing air available.
No help available
519
Cause
Sealing air is not (no longer) available.
Solution
Check sealing air.
0x0001F201 Machine not implemented.
No help available
522
Contact service
0x0001F301 Settings are saved.
No help available
523
Contact service
0x0001F401 The blower has already been in use for more than 6000 h. Please contact the service
department.
No help available
524
Cause
The vacuum generator has already been in use for more than 6000 h.
Solution
Contact your service partner
0x0001F501 The blower has already been in use for more than 8000 h. Only half the power can
still be used.
No help available
525
Cause
The vacuum generator has already been in use for more than 8000 h. Only a
maximum of half the power is still available
Solution
Contact your service partner
0x0001F603 Callback functions could not be registered.
No help available
526