Operating instructions

Cleaning and maintenance G3 Series
Maintenance jobs
7-24
000001,07,12-2008, jmu
7
7.7.11 Draining the maintenance unit condensation water
Tools and materials
# Container
Ensure, that following precondition is fulfilled:
The machine is switched off.
Procedure
Fig. 7-14 Drain condensation water
Disposal !
The condensation liquid from the water separator is contaminated with oil. Therefore
the liquid must be disposed of correctly according to the specific national regulations.
Set the main switch of the maintenance unit to Off
Hold a container under the drain
Open the drain screw
Allow the liquid to drip into the container and shut the drain screw