Operating instructions

Product description G3 Series
Technical information
2-18
000003,04,02-2009, jmu
2
Additional specifications and requirements can be found in the chapters "Modules,
tools, options, material handling"
2.8.5 Control unit
Execution
4-axis control (X, Y, T, Z)
Variable, prognostic vector processing.
Software
Interface
1 MB input buffer with replot function
Setting - pressure regulator maintenance unit
(P3)
0.6 MPa
Control of vacuum zones, supply of various
modules, tools
Value Units
Operating pressure 0.6 - 0.8 MPa
Min. air flow 20 l/min
Setting - pressure regulator maintenance unit
(P2)
0.6 MPa
Conveyor feeding clamps Value Units
Command set HP-GL, extended
Data format ASCII
RS-232C / V24 600 - 38200 Baud