Operating instructions
Controls and operation G3 Series
Controls
4-10
000010,06,02-2009, jmu
4
4.3.2 Emergency stop switch
Attention !
Risk of damage to the machine.
Only use the emergency stop switches to switch off the machine in an emergency -
not for standard shutdown.
• Emergency stop switches are part of a protective circuit
• They allow the machine to be switched off quickly in a dangerous situation
Fig. 4-8 Emergency stop switch
The machine is fitted with four emergency stop switches as standard. They are
located as follows:
• 1 x on the operating console
• 3 x on the side support covers
Consequences of pressing an emergency stop switch:
• The drive motors are brought to a standstill and then are isolated from the energy
supply.
• Safety-related units (modules, tools, auxiliary drive, sheet feeder etc.) are isola-
ted from the energy supply.
• Units that are not safety-relevant or that are important for the operation of the de-
vice (vacuum, operating unit, dust extractor, compressor etc.) remain switched
on