User's Guide
Table Of Contents
- Quick Reference Guide
- The following chart lists the basic functions of your system, and the keys to press for each func...
- Turn on system (Away): [access code], leave through entry/exit door 9 OR press Away (if enabled)
- Turn on system (Stay): [access code], do not leave premises 10 OR press Stay (if enabled)
- Turn off system: [access code] 8
- Turn on system (No Entry Time): [access code] 11
- Turn on system (Quick, if enabled): (from Ready state) 10
- Turn on rest of system (if Stay armed): OR press Interior (if enabled) 10
- Exit premises when system on: OR press Exit (if enabled) 12
- Turn off zones (Bypass): [two-digit zone number(s)], to exit 15
- Test system [master code] 17
- Send Fire message: (press & hold for 2 seconds, if enabled) 14
- Send Auxiliary message: (press & hold for 2 seconds, if enabled) 14
- Send Panic message: (press & hold for 2 seconds, if enabled) 14
- Silence fire alarm: [access code] 13
- Silence intrusion alarm: [access code] 14
- Turn door chime on/off: to toggle on or off 20 OR press Chime (if enabled)
- Check alarm memory: 14
- Check troubles 16
- Set time and date: [master code] 20
- Table of Contents
19
Section 6: Customizing Your System
This section describes how to customize your system to suit your needs. Refer to
this section for detailed instructions on programming access codes and setting
time and date.
Programming
Access Codes
The master code (code 40) can be used to program system options, arm and dis-
arm the system and program other access codes. You can program up to 32 addi-
tional access codes (01 through 32). Other access codes, such as system
supervisory and duress codes, are available. Contact your installer for more infor-
mation.
1. Press [Master Code]. The red (Armed) light will turn on and the Program-
ming icon will be displayed.
2. Enter the two-digit number of the access code you want to program (01-32 for
access codes, 33 and 34 for duress codes, 40 for master code, 41 and 42 for
supervisor codes). If an access code already exists for the code number you
have selected, it will be replaced by the new code.
3. Enter the new [code]. Access codes must be four digits unless otherwise indi-
cated by your installer.
NOTE: Do not use the factory default or obvious codes
such as [1111] or [1234].
4. To exit access code programming, press .
5. Record your new codes on the “System Information” on page 29 in this book-
let.
Access Codes
can be custom programmed to limit the options of the user. When
a new access code is programmed, it is programmed with the attributes of the
code that was used to enter [*] [5] programming (attributes 1,3,7).
(1) Arming, disarming, alarm reset allowed.
(2) Future Use.
(3) Zone Bypassing allowed.
(4) Future Use.
(7) Bell squawk on arming/disarming.
(8) Future use.
To change the attributes listed above perform the following:
1. Press [Master Code][9]
2. Enter the number of the code you want to modify [01 to 32]. The Master code
cannot be modfied.
3. Press the digit corresponding to the attribute you wish to remove or add.
*
5
#
*
5