Installation Manual

18
S E C T I O N 7
Troubleshooting
1. When I enter the 2-digit zone number when adding a wireless device, the
keypad gives me a long beep.
You cannot enter ESNs unless the RF5501-433 is properly connected to the Keybus. See
sections 1 & 3 for instructions on setting up and wiring the RF5501 module.
2. I have entered the ESN for the device but when I violate the device, the zone
does not show open on the keypad.
Check the following:
Ensure the ESN has been entered correctly
Ensure that the zone is enabled for the partition (if partition programming is used).
Ensure that the wireless zone is not assigned to a zone used by PC5108 modules, an
on-board zone or a keypad zone.
Ensure that the zone is programmed for something other than “Null Operation and that
the wireless zone attribute is turned on.
3. When I try a module placement test I get no result or “Bad” results.
Check the following (see sections 5.1 and 5.2 for more information on testing devices):
Verify that you are testing the correct zone
Verify that the correct ESN was entered when the device was enrolled
Verify that the device is in range of the RF5501-433. Try testing the device in the
same room as the receiver.
Confirm that the RF5501-433 is properly connected to the Keybus.
Check that you are testing the zone correctly.
Check that the batteries are working and installed correctly.
Look for large metal objects that may be preventing the signal from reaching the
RF5501-433.
The device must be located where consistent “Good” results are obtained. If several
devices show “Bad” results, or if panic pendants and wireless keys operate inconsist-
ently, move the receiver.
4. The LED on the motion detector does not turn on when I walk in front of the
unit.
The LED is for walk test purposes only. See your WLS904-433/WLS904P(L)-433
Instruction Sheet
for walk test instructions.