DS1 User Manual Table of Content Safety instructions Intended use 3 4 1. HARDWARE Parts list: DS1 Advanced System / DS1 System DS1 System Specifications Hardware and Firmware Versions What's included PSU interface Module setup 5 5 6 7 8 10 12 2.
DS1 User Manual Safety instructions Safety instructions 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. Please read through these instructions carefully before operating the DS LED Lighting System, and keep these instructions for future reference. There are numerous safety instructions and warnings that must be followed for your own safety. DS LED Lighting Systems are not intended for residential use. They are intended for use in a professional studio or film set.
DS1 User Manual Intended use Intended use This product has been designed as a professional illumination tool for dry environments. Please always follow the safety instructions. Any usage other than described in this manual is not advised and can damage the product and lead to risks such as fire, electric shock, etc. You are not allowed to modify the product.
DS1 User Manual 1. HARDWARE / DS1 /Ds1 Dual System 1. HARDWARE Parts list DS1 Dual System DS1 System 1 Pcs – 2 Pcs – 2 Pcs – 2 Pcs – 2 Pcs – 4 Pcs – 2 Pcs – 1 Pcs – 1 Pcs – 1 Pcs – 1 Pcs – 1 Pcs – 2 Pcs – 1 Pcs – 1 Pcs – 1 Pcs – 6 Pcs – 1 Pcs – 1 Pcs – 2 Pcs – 2 Pcs – 12 Pcs – 1 Pcs – 1 Pcs – 2 Pcs – 1 Pcs – 1 Pcs – DS1 Dual Cardboard Box DS1 PSU DS1 AC/DC Converter DS Light Module RGBW DS Tripod Mount DS Eccentric Lock DS Light Module Cable 2ft/0.
DS1 User Manual 1. HARDWARE / DS1 System Specifications DS1 SYSTEM SPECIFICATIONS: Module type: RGBW LED Beam angle: 20 degrees Remote control options: Wired (RDM/DMX), Wireless (Art-Net). Operating temperature range: 0ºF ~ 115ºF/-20ºC ~ 45ºC Input power: 90-260 VAC (Worldwide)Power Convertor/ 12 to 36 VDC Battery Cables from PSU to LED module: 2ft/0.75m Maximum power draw per DS1 PSU: 100 W Dimensions of a single light module: 116 x 116 mm/4 x 4 in square, 2.8lb/1.3kg Dimensions of DS1 unit: 12 x 4.0 x 4.
DS1 User Manual 1. HARDWARE / Hardware and Firmware Versions Hardware and Firmware Versions This user manual covers features up to v2.67.5 firmware. Some functionality may not be available with earlier firmware versions Firmware updates are released on a semi-regular basis. We recommend updating to the latest available firmware version so all product features are available. Each release has substantially different DMX modes.
DS1 User Manual 1. HARDWARE / What's included What's included: PSU - Can also be referred to as Ballast. The brain of the operations, gives power and controls the light module. Light module - has 16 RGBW LEDs under its collimator lens. Each light module has been factory calibrated with a specific profile saved into it. Constant color coordinates are kept through the dimming range using high-precision, multi-dimensional LUTs (lookup tables). The Light module stores DMX Addressing info.
DS1 User Manual 1. HARDWARE / What's included Eccentric Lock - Multiple purpose spring loaded locking lever. Diffusion Clip - Clip designed to hold the Holographic diffusion lens onto the light module. Tripod Mount - Modular tiltable tripod mount that is both a baby and junior pin. AC/DC Converter - The DS1 AC/DC Converter from Digital Sputnik provides universal 90 to 260 VAC current to the DS1 power supply.
DS1 User Manual 10 1. HARDWARE / PSU interface PSU interface Screen Jog-wheel Rotating jog-wheel with push functionality. Center of jog-wheel acts as OK button. Screen Gateway to your DS1 system. All color parameters, settings and system information is presented on here. For easier control, the orientation of the display screen will rotate 180°depending on the position of the PSU. 1. 2.4 Ghz WiFi module antenna Removable WiFi antenna.
DS1 User Manual 1. HARDWARE / PSU interface 5. V mount battery plate Each PSU is equipped with a single V-Lock battery plate. The input is 12 to 36 VDC* There is no power button to be found on the DS1. When wanting to interrupt power, remove battery/batteries from the PSU or disconnect the AC/DC power connector. *If needing more than one battery mount an extra battery plate can be purchased and installed separately.
DS1 User Manual 1. HARDWARE / Attaching Tripod Mounts Attaching Tripod Mounts The cable socket is always on the top left corner Security Washer The cornerstone of assembling DS1 system together is the eccentric lock. The DS1 PSU, Light Module and the Tripod Mounts all have the same eccentric lock sockets for fixture building purposes. This allows for great diversity for shaping your light fixture to your needs.
DS1 User Manual 1. HARDWARE / Module setup Module setup The DS1 PSU has two eccentric lock mounts. One on the short and one on the long side of the PSU. The mounting procedure is identical to the tripod setup. The “default” mounting point for the module is on the short side of the PSU. It is important to make sure before the Light Module is Fastened to know the orientation of the PSU so that the input sockets of the PSU (DMX IN, AC/DC) would be facing downwards.
DS1 User Manual 2. CONTROL / Color page / Color control 2.CONTROL Color page Color control From all menu pages “COLOR” menu will always be accessible from the bottom of the screen for quick manual control of the light modules. Use the jog-wheel to navigate to “COLOR” menu and press OK when the page name is highlighted. Turn the jog-wheel slowly for precise control. The incremental raise of the value is influenced by the speed of which the button is turned.
DS1 User Manual 2. CONTROL / Color page / Color control Temperature presets, are as follows: 1500, 3200, 5600 and 10000 K. Using the twist knob will allow increment changes of 100K. 3. Saturation (SAT) - is the amount of color mixed into the white light. It is also expressed in percentages, but it can go from -120 to 120%. The SAT parameter has the possibility of reaching 120% both in the negative and positive sides.
DS1 User Manual 2.
DS1 User Manual 2. CONTROL / Color page / Color control Please note that ITSH settings will be recorded after 6 seconds after manual input and after five minutes when consistent DMX values are sent by an external controller. These will be the starting ITSH settings after PSU reboot. When DMX communication is active and DMX packet values are changing constantly (light animation) the ITSH values are not saved.
DS1 User Manual 2. CONTROL / Setup page Setup Page Allows the user to alter specific functionality and check working information about the PSU and light module. 1 2 3 4 To navigate between the DS DMX page, SETUP and WiFi pages, press OK when the page name is highlighted and use the jog wheel. 1. Remote - indicates the remote control mode either DMX(Wired), Art-Net(Wireless) or OFF. Select OFF to stop control by an outside device if you intend to control your lights from the PSU. 2.
DS1 User Manual 2. CONTROL / Setup page 3. Curve - changes the dimming curve of the value range. It can be set so the value is increased and decreased linearly(LIN) or by a square factor(SQR). Note that when using “LIN” the light output is brighter on the whole dimming interval but the maximum output of the module is not altered with this setting. 4. Module data.
DS1 User Manual 2. CONTROL / DS DMX page DS mode ON/DS ADDR “DS mode” “ON” should only be used when controlling DS1 from the “DS DMX” iOS app. When in need to change DMX universe or DMX mode set “DS mode” to “OFF” under “Setup” menu. DS mode is a more simplistic approach to DMX setup, eliminating the need to orientate between DMX modes, universe selection and also making channel numbering less cumbersome. When the DS Mode is in use, the DS DMX page will be named as DS ADDR.
DS1 User Manual 2. CONTROL / DS DMX page If “DS MODE” is ”ON”, the DS1 will assume the standard DMX subset of the “DS16” personality. (Universe is 0, Net 0, Subnet 0) DS mode OFF/ DMX ADDR When “DS Mode” is set to “OFF” the basic DMX Mode is in use. The starting page will be named DMX ADDR.
DS1 User Manual 2. CONTROL / DS DMX page Various DMX personalities Mode Description DS16 DS8 ITSH16 Standard DS modes. DS MODE=ON uses DS16 by default. ITSH8 XFADE16 XFADE8 RGB8 (no fan control) Number of channels Similar to DS8/16, with positive saturation. Crossfade modes Basic RGB + Temperature modes iRGB8 ARRI6 ARRI1 10 5 10 5 16 9 4 6 ARRI RGBW crossfade modes 17 + 3 unused = 20 9 + 3 unused = 12 *Note: For more information about DMX personalities visit www.digitalsputnik.com.
DS1 User Manual 2. CONTROL / WiFi page WiFi page Network information can be found on the WiFi page of the menu. To navigate between the DS DMX page, SETUP and WiFi pages, press OK when the page name is highlighted and use the jog wheel. This page is only visible when the “REMOTE” mode on the setup page is set to “WiFi”. Depending on whether the PSU is set to Server or Client mode, the information presented on the WiFi page will differ: Server mode: The WLAN Server mode is the default mode.
DS1 User Manual 2. CONTROL / WiFi page Client mode: Through the DS DMX app for iOS, it is possible to connect the DS1 to another DS Art-Net enabled PSU, or to an existing WiFi network (a wireless router). If possible connect the DS1 to a DHCP enabled router. This ensures that the IP address, gateway, DNS1 and DNS2 are automatically assigned to the fixture by the network. If needed the IP address of the handle can be altered using DS DMX app.
DS1 User Manual 2. CONTROL / WiFi page Reset WIFI This setting is used to reset the WiFi module to the default Server (Access Point) setting with the Serial Number of the DS1 PSU as its network name (SSID). The Serial Number can be checked on the side of the DS1 PSU. Press OK a total of 3 times to activate this function. The WiFi reset takes about 15 seconds to perform. Defaultly there is no password needed to connect to the WiFi network.
DS1 User Manual 2. CONTROL / WiFi page Factory reset A factory reset can be performed in order to change PSU settings to their default values. This option is located on the bottom of the SETUP page. The following parameters will be changed: • Intensity = 0%, Temperature = 5600K, Saturation = 0%; Hue = 120 degrees. • DMX personality is set to DS 16. • All cached Lamp Unit Calibration Tables (LUTs) will be cleared.
DS1 User Manual 2. CONTROL / Upgrade / Bootloader mode / Upgrade All Digital Sputnik PSUs are upgradeable by the user. A Windows or macOS Upgrade Utility can be downloaded from the Digital Sputnik webpage. The update can be performed via the DS WiFi module, or through a wired connection (DMX to USB cable with FTDi chip available for purchase at www. digitalsputnik.com). Perform a Wifi reset before upgrading DS1 over WiFi.
DS1 User Manual 3. WARNING CODES Warning codes (flashing codes) Code Description ArtDMX ArtDmx stream is incoming from the WiFI module. Works under Remote=WiFi only. DMX DMX stream is incoming from the XLR-5 pin on the DMX/RDM handle. Works under Remote=DMX only. “LOADING WIFI” or “AWAITING WIFI” WiFi settings are being acquired from the WiFi module. If there are problems with communications this message may stay active in the WiFi menu indefinitely. “RESETTING WIFI” WiFi is being manually reset.
DS1 User Manual 3. ERROR CODES Error codes Critical/blocking codes; the device attempts to clear these every 30 seconds. A manual attempt to clear the error can also be made on the DS1 from a single device or Master (topmost) device in a stack, by pressing OK when the code is on screen. But when the problem persists the code reappears immediately.