User Manual

FACTORY DEFAULT SETTINGS
Factory reset
1. Make sure the detector is powered on.
2. Follow the diagram below to locate the reset button on the side of the illuminator.
3. Unscrew and open the cap and press the reset button according to the following options:
1-2 seconds press: power cycle. The LED will flash once the button is released.
3 seconds press: reset the network and user credential. The LED will flash 3 times after
3 seconds.
10 seconds press: reset to factory setting (erase all). The LED will flash 3 times after 3
seconds, then will turn on again when the button is released after 10 seconds.
4. The unit’s IP address and login details are now reset back to factory values.
ENSURE THAT THE IP68 RATED COVER IS CORRECTLY FITTED AND ATTACHED TO THE NETWORK CABLE. IF
THIS IS NOT FITTED CORRECTLY MOISTURE CAN GET INTO THE CONNECTOR AND MAY CAUSE THE UNIT TO
MALFUNCTION. THIS WOULD VOID THE WARRANTY ON THE PRODUCT.
Mount
Reset
Shows
LED
Pressure
relief valve
IM Ethernet
cable with
IP68 connector
Safety Warning
When the lamp is running, it is hot to the touch. Before touching, switch o the
illuminator and allow to cool for a minimum of 10 minutes.
The illuminator should be positioned so that prolonged starring into the illuminator at a
distance closed than 1m is not expected.
The light source of this illuminator is not replaceable, when the light source reaches its
end of life the whole illuminator should be replaced.
If the flexible power cord of the illuminator is damaged it should be exclusively replaced
by an authorized service agent.
This equipment is not suitable for us in locations where children are likely to be present.
8