Technical data

Linkage with PLC
116 VIPA GmbH CP486 00/14
PLC program (permitted 0...255)
Error acknowledge message of handling module:
= 0 no error occurred
><0 error occurred, error number in PAFE-Byte:
3 basic bank number is not divisible by 8
4 bank is not existent (acknowledgement delay at bank access)
5 bank is not synchronized yet by the CP
10 invalid job number (out of 1...127)
12 no DB open for indirect parameterization
16 DB for indirect parameterization too short
20 invalid marker word no. for ANZW (out of 0...198)
21 invalid marker word no. for DOSP (out of 0...198)
Parameter storage in a DB if parameterization is indirect:
DL DR
A-NR points to the beginning
INSS
A-NR
DOSP
RWAW
PAFE is not parameterizable indirectly
0 can be parameterized at all other formal operands (SS, RWAW) because these are not evaluated at
indirect parameterization.
Scratch markers used: MB200-255