Technical data
BIOS and System Programming
78 VIPA GmbH CP486 ⋅ 00/14
4.3.8.6 Configuration Example: Linear Operation
Configuration:
Number of banks: 1 (In the linear operation only 1 bank is possible)
Bank capacity: 8 KByte
PLC initial address of the bank: 8000(hex)
Specified bank numbers: 0 (Note: for linear operation the bank number must be 0)
Bank selection in the PLC: not possible
Registerinhalte:
Ident register (C800:1F80): 00(hex) (corresponds to the highest bank number)
Bank initial register 1 (C800:1F84): 00(hex)
Bank initial register 2 (C800:1F86): 06(hex)
Configuration register (C800:1F82): E0(hex)
Interrupt reset register (C800:1F8E): 00(hex)
Interrupt in the CP486:
In the CP486 an interrupt is initiated by an PLC write access to the highest
bank element at address 9FFF(hex).
Address assignment:
Bank PLC address CP486 address
0 8000 - 9FFF C800:2000 - C800:3FFF