Use & care guide

10
Wrong polarity Protection,
Negative delta voltage protection,
Zero delta voltage protection,
Timer Protection,
Temperature protection via built-in cooling fan,
Cooling fan failsafe protection.
The REZA Pro, RBC889 complies with the following International
Standards for electrical safety:
AS/NZS 3108:1994; AS/NZS 3350.1:2000; AS/NZS 3350.2.29:2001
EN 206041A; EN 60335.1; EN 60335.2.29
EMC & C-Tick (AS/NZS 1044:1995); CE (EN50082-1)
FCC Part 15 Class B - ANSI C63.4-1992
CSA Technical Information Letter No. Q-13 (Battery Charger for Charging
Alkaline Batteries)
QUICK START
STEP 1: TURNING THE CHARGER ON
Plug the 12V switching power supply into a proper indoor electrical outlet
and connect its output cable to the 12V input socket at the back of the
charger. Switch on the power from the mains, the blue LED lights up
indicating the charger is active and ready for use.
STEP 2: CONNECTING THE BATTERIES TO THE CHARGER
Ensure that batteries are in good condition before charging them. DO
NOT attempt to charge any battery that has sign of rust, chemical leakage
or deposit on the terminals. These should be disposed of immediately to
avoid subsequent damage to charger and/or electronic devices.
o Although battery leakage found on some faulty, damaged or old
batteries will typically not cause immediate damage to unprotected skin,
it is best to avoid contact, or if contact occurs, immediately wash the
exposed area with soap and water.
ENGLISH