Use & care guide
www.procontechnology.com.au Phone: (03) 98306288 FAX: (03) 98306481
NGL
IS
H
5. The green light does not turn on or blink even when there is a
battery in the s
l
ot
.
• Loose or bad contact between the battery and the metal plate in the slo
t
may exist, reinsert the battery properly or gently move or rotate
t
he
battery until good contact is established. If the LED remains off,
t
ry
relocating the battery to a different slot to ensure problem is not caused
by the slot. Should the LED still not respond, the battery is dead due
t
o
internal open circuit or chemical / rust deposit at its terminals. Remove
and dispose of the battery thoughtfully. The battery contacts may also be
dirty. Refer to the cleaning section for cleaning procedure
.
6.
Charger rejects many batteries. How to verify that the charger is
work
i
ng proper
l
y
.
• There are two simple tests to verify if the charger is functioning properly
or not. If it passes the tests below, then the charger is working as i
t
should
.
o Put a NEW (fresh from a packet) AA alkaline battery into the charger
.
After a short while, the green light should turn ON constant indica
t
ing
the battery is detected as "FULL".
o Put a known good-condition NiMH AA rechargeable battery into
t
he
charger. The green light should be blinking away for at least 10
minutes, indicating that the battery is recognized as “rechargeable”
and charging continues until the battery is fully recharged
.