Technical data

Digital PRIORIS XL ServerDigital PRIORIS XL Server Service NotesService Notes
MCS Logistics Engineering - NijmegenMCS Logistics Engineering - Nijmegen 8787
P
R
I
O
R
I
S
X
L
Appendix A Service Notes
This appendix contains the current Service Notes for the PRIORIS XL product line.
Known Server limitations.
Do not install a 5¼-inch diskette drive in the top drive bay. EMI shielding might cause elecrical
shorts to the etch on the diskette drive’s circuit board.
Due to the length of the IDE cable, make sure IDE drives are installed in drive bay slots 1 and 2.
Otherwise, the IDE cable will not reach the IDE drive’s connector.
PCI IDE expansion boards will not work in the server.
The time required to boot the server might increase when a DE422 network card is installed in a
server that uses a Pentium CPU module.
Recommended Tools
The following tools will be needed for servicing Digital PC systems. Note that test equipment must be in
calibration.
Multimeter (4 1/2 digit)
A philips screwdriver
An antistatic wrist strap
Other Needed Materials
Cleaning agent should be an all purpose cleaner that is used in-house.
Required Special Tools.
None.