Owner`s manual

3–8 TF867 Local Programs
3.4.4 SET Command
Use the SET command to set, or change, internal TF867 subsystem
parameters. The syntax for the SET command is:
PARAMS> SET parameter value
In the previous example, parameter is the name of the parameter to
be set, and value is the value you want to assign to the parameter. If
abbreviated, the first matching parameter is used without regard to
uniqueness.
See Table 3–1 for a summary of TF867 subsystem parameters available
when using the SET command.
CAUTION
If you type EXIT at the PARAMS> prompt without saving your
modifications, the system displays the message:
Parameter modified but not written. Still Exit? [Y/(N)]
If you answer YES, the system returns to the VMS prompt ($).
Your modifications are not saved.
If you answer NO, the system returns to the PARAMS> prompt.
To save your modifications, enter WRITE at the prompt, and
then EXIT. See Section 3.4.6 for more information on the WRITE
command.
3.4.5 STATUS Command
The STATUS command provides status about the operation of the
subsystem.