Owner`s manual

2.5.1 Unpacking Rackmountable Models (TSZ07-AA, -DA)
The rackmountable models are shipped in one large carton and one
smaller carton. The large carton contains the TSZ07 tape transport
cabinet. The smaller carton contains documentation, a cleaning kit, a
SCSI cable, a power cord, and a reel of magnetic tape. A SCSI terminator
is mounted on the rear of the TSZ07. Hardware for rack-mounting the
tape drive is also included.
CAUTION
Single-ended and differential SCSI busses require differ-
ent termination. Be sure to use the terminators marked
"differential" with the differential drive (the terminators
are supplied with the drive).
After unpacking the TSZ07, place the TSZ07 on a flat work surface and
check the shipping documents to ensure that the correct model has been
shipped. If anything is missing, damaged, or incorrect, contact the dealer
from whom the equipment was ordered.
Remove any tape securing the front door (see Figure 2–1).
The TSZ07 is shipped with a plastic packing ring on the take up
hub which must be removed before it can be operated. To remove
the packing ring, place the TSZ07 in the tape access position, as described
in the following section.
2.5.2 Removing Packing Material from the TSZ07-CA, -FA
To place the TSZ07 in the tape access position, perform the following:
1. Position the TSZ07 so that the top is free to open.
2. Raise the top cover and place the cover retaining arm in the recess
next to the tape path. See Figure 2–15.
2–26 Installation