User Guide

DigiTech S-DISC™ SysEx
Procedures
13
13
Procedures
DigiTech S-DISC™ SysEx
REQUEST PARAMETER V
ALUE (17h)
NOTE: This procedure is only implemented in the GSP-2101 Version 3.xx software.
SYS_HEAD, 17
(h), mm
1
, mm
2
, pp
1
, pp
2
, F7(h)
mm The effect module’s position in the Algorithm
pp The Paramter’s position in the effect module.
When a Request Parameter Value procedure is received, the device will respond with a
Receive Parameter Value procedure.
RECEIVE P
ARAMETER V
ALUE (18h)
NOTE: This procedure is only implemented in the GSP-2101 Version 3.xx software.
SYS_HEAD, 18
(h)
, mm
1
, mm
2
, pp
1
, pp
2
, vv
1
, vv
2
, F7(h)
mm The effect module’s position in the Algorithm
pp The Paramter’s position in the effect module.
vv The Parameter’s value
When a Receive Parameter Value procedure is received, the device’s valid Parameter
value is updated with vv.
RECEIVE KEY SCAN CODE (54h)
SYS_HEAD, 54(h), cc, F7(h)
cc Code for the Key Scan
The Receive Key Scan Code procedure is used to emulate a button press on the front
panel of a DigiTech Device. See the Key Scan Co
de Maps (page 18) for a list of Key
Scan codes.