Inc Sound Module Decoder - Manual

© 2017 Digitrax, Inc.
www.digitrax.com- 60 -
CV62 also controls how fast/slow the programmed effect operates. This lets
you adjust the flashing rate of the lights.
The settings in CV62 affect all function outputs on the decoder.
The default value for CV62 is 00 for no keep alive brightness and fastest func-
tion operation rate.
Use our online CV calculator at www.digitrax.com/support/cv to compute the
CV values for your specific situation. Or use the following table to determine
the appropriate CV value for CV62. Simply choose a value for each character-
istic and add them together to get the CV value to program into CV62.
NOTE: Lamps produce better effects. LEDs cannot be set to go completely
off and are not able to simulate lighting effects as well as incandescent lamps.
TABLE XIII: CV62 Rate and Keep Alive
Characteristic Value to add
Keep Alive Brightness/Base-
line O Voltage for incan-
descent lamps
0-15
0=Lamp goes completely o
15=maximum keep alive brightness
For LEDs this should be 0
Rate of eect programmed 0, 16, 32, 48, 64, 80, 96, 112, 160, 176, 192,
208, 224, 240
0=fast rate
240=slowest rate
Start with 64 and adjust from there
9.6 Ditch Light Hold Over Time CV63
If you are using the ditch light effect in conjunction with F2, CV63 lets you
set up a hold over time to control how long the ditch lights continue to blink
after F2 turned off by releasing the key on the throttle. Remember that F2 is a
momentary key on most Digitrax throttles that will keep Function 2 on as long
as you hold the key down and then turn Function 2 off when you release the
key. This allows the ditch lights to be on steady during regular operation and to
begin alternate flashing when F2 (usually the horn) is activated and to continue
flashing alternately for a predetermined length of time after F2 is released; just
like the prototype. A value of 00 yields no hold over time, a value of 40 yields
a realistic time of approximately 3 seconds. A value of 255 yields approximate-
ly 20 seconds hold over time. Use our online CV calculator at www.digitrax.
com/support/cv to compute the CV values for your specific situation.
Note: The settings in CV63 affect all function outputs on the decoder.